> ## Documentation Index
> Fetch the complete documentation index at: https://calcs.com/docs/llms.txt
> Use this file to discover all available pages before exploring further.

# Calculate Wind Loads: Components and Cladding (ASCE 7-22)

> Calculate MWFRS and components and cladding wind pressures to ASCE 7-22 for low-rise buildings, with code references on every output.

<div className="calc-details not-prose">
  <div className="calc-details-item">
    <div className="calc-details-chips"><span className="calc-chip calc-chip--region">United States</span><span className="calc-chip calc-chip--primary">ASCE 7-22</span></div>
    <div className="calc-details-head"><span className="calc-card-icon">    <img src="https://mintcdn.com/clearcalcs/32krV4BnKnXD1TTf/images/calculator-icons/b68591442c50099eb73a22a3d2ee044f224dc03c84592f2ca03ffb57f8f0667b.svg?fit=max&auto=format&n=32krV4BnKnXD1TTf&q=85&s=56a474c463ec42b923c6e7cc1ec9ddb5" alt="" width="24" height="24" loading="lazy" data-path="images/calculator-icons/b68591442c50099eb73a22a3d2ee044f224dc03c84592f2ca03ffb57f8f0667b.svg" /></span><p className="calc-details-name">Wind Loads (ASCE 7-22)</p><a className="calc-details-run" href="https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22">Run the calc</a></div>
  </div>
</div>

<div className="calc-answer">
  Calculate MWFRS and C\&C wind pressures to ASCE 7-22 for low-rise buildings. Velocity pressure, pressure coefficients, and design pressures are shown alongside code references. Handles straightforward sites and detailed overrides when exposure, topography, or directionality warrants it.
</div>

<Tip>
  **Instantly create a new Wind Loads (Components and Cladding) calculation by clicking here:**

  [**Create Wind Loads Calculator**](https://calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=Components+and+Cladding)

  *(This link automatically opens a new project and sheet in Calcs.com.)*
</Tip>

#### Background

The Calcs.com Wind Load Calculator for Components and Cladding (C\&C) provides a streamlined and accurate solution for calculating wind pressures in accordance with **ASCE 7-22 Chapter 30**. This calculator helps structural engineers quickly determine design wind pressures acting on specific building elements (such as purlins, girts, studs, and roof decking) and cladding, taking into account a wide range of building configurations, exposure conditions, and the new tornado load requirements introduced in ASCE 7-22.

The calculator determines the required corner, edge, and field zones, wind pressure coefficients, and resulting design pressures, providing a comprehensive analysis for various design scenarios including Enclosed, Partially Enclosed, Partially Open, and Open buildings.

<Note>
  **Want to learn more?** Check out our [Wind Load Calculations to American Standards webinar](https://calcs.com/webinars/wind-loads-residential) to learn how to analyze wind load requirements for residential buildings based on the American Standards, including worked examples using our wind load calculators.
</Note>

#### Project Defaults

You can select whether the calculator will use the project defaults, where you can set the building code used for your project, as well as wind, snow, seismic, and general criteria.

In particular, if you provide the project address in the Project Details as well as the **Risk Category** and **Exposure Category**, the basic wind speed and ground elevation will be automatically determined and used in your wind calculator.

If you select to **Override Project Defaults**, you must manually input the following:

* **Basic Wind Speed (V)**
* **Exposure Category** (B, C, or D)
* **Building Risk Category** (I, II, III, or IV)
* **Tornado-Prone Region status**
* **Tornado Speed (V\_T)** (if applicable)

<img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-PROJECT-DEFAULTS-OVERWRITTE.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=145bf263208cdb20c81562f53268189f" width="550" alt="Wind Loads Project Defaults Override" style={{ width:"70%" }} data-path="images/WIND-PROJECT-DEFAULTS-OVERWRITTE.png" />

#### Key Properties

Under the key properties section, you can select **Type of Calculation**. For this article, we focus on **Components and Cladding**.

* **Effective Roof Member Wind Area** and **Effective Wall Member Wind Area**: tributary area of the member being designed (for example, a single roof truss or wall stud). These values set external pressure coefficients ($GC_p$) when **Individual Effective Area per Wind Zone** is **No**.
* **Individual Effective Area per Wind Zone**: set to **Yes** to define different effective areas in the **Individual Effective Area** table for each zone. Parapet inputs are hidden when this is **Yes**.

<img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-KEY-PROPERTIES.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=736d5996e5f9c39460972ed7e7f8474a" width="550" alt="Wind Loads Key Properties" style={{ width:"70%" }} data-path="images/WIND-KEY-PROPERTIES.png" />

#### Building Properties

This input allows you to define the geometry and enclosure classification of the structure.

* **Roof Type:** Supported roof types include **Flat**, **Gable**, **Hip**, and **Monoslope**.
  * Depending on the selection, you will define properties such as **Roof Pitch**, **Roof Top Height** ($h_t$), and **Eave Height** ($h_e$).
* **Dimensions:** Define the Building Width ($w$) and Length ($l$).
* **Enclosure Type:**
  * **Enclosed:** A structure with controlled openings (e.g., typical office buildings).
  * **Partially Enclosed:** A structure with large openings on one wall causing internal pressure buildup (e.g., a warehouse with a large open door during a storm).
  * **Partially Open:** A structure with significant openings on multiple walls.
  * **Open:** A structure with no walls, where wind flows freely over and under the roof (e.g., carports, canopies, agricultural sheds, and covered pavilions). For Open enclosures, the calculator uses free-roof net pressure coefficients ($C_N$) per **Cl. 30.5**, tabulated across interior, edge, and corner wind zones with three effective-wind-area bands per zone. Per Note 3 on the governing figures, interpolation is permitted only on roof angle ($\theta$), never on effective wind area. A minimum net design pressure of **16 psf** is enforced per Cl. 30.2.2. Open enclosure support is currently limited to **monoslope** and **gable** roof shapes, with a single effective wind area applied uniformly across all zones.
* **Large-Volume, Unpartitioned Building?** (appears when Enclosure Type is **Partially Enclosed**): set to **Yes** for a single, unpartitioned large-volume building such as an arena, aircraft hangar, or open-interior warehouse. This exposes **Unpartitioned Internal Volume** ($V_i$) and **Total Area of Envelope Openings** ($A_{og}$), and applies the Internal Pressure Reduction Factor $R_i$ per Eq. 26.13-1 to $GC_{pi}$. Defaults to no reduction ($R_i = 1.0$).

<Note>
  **Tornado loads with Open enclosures**

  On ASCE 7-22 sheets, the Chapter 32 tornado load tables are not displayed for Open enclosures because that procedure is not yet implemented for free roofs. See the in-calculator note for the current scope.
</Note>

<img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-BUILDING-PROPERTIES.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=75f1fb6ff7c1ee42284bdb1a87cc4213" width="550" alt="Wind Loads Building Properties" style={{ width:"70%" }} data-path="images/WIND-BUILDING-PROPERTIES.png" />

#### Terrain Properties

The calculator can automatically determine the **Ground Elevation Above Sea Level** if a project address is provided, calculating the Ground Elevation Factor ($K_e$) per ASCE 7-22 Section 26.9. Alternatively, a custom elevation can be entered.

**Topographic Effects:** If the site is located on a hill, ridge, or escarpment, you can toggle **Hill or Escarpment Present?** to "Yes". You must then select the **Hill Shape** (2D Ridge, 2D Escarpment, or 3D Axisymmetrical Hill) and provide:

* **H:** Height of feature relative to upwind terrain.
* **L\_h:** Distance upwind of crest to mid-height of feature.
* **x:** Distance from crest to building site.

These inputs calculate the Topographic Factor ($K_{zt}$) per ASCE 7-22 Section 26.8.

<img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-TERRAIN-PROPERTIES.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=9b798287e1d1cd337efa6aa07618a551" width="550" alt="Wind Loads Terrain Properties" style={{ width:"70%" }} data-path="images/WIND-TERRAIN-PROPERTIES.png" />

#### Tornado Load Parameters (ASCE 7-22 Chapter 32)

A significant addition to ASCE 7-22 is the requirement to check for Tornado Loads (Chapter 32). The calculator automatically performs the applicability check based on:

1. **Risk Category:** Generally applies to Risk Category III and IV structures (and some others depending on parameters).
2. **Tornado-Prone Region:** Whether the site is mapped in the tornado-prone region (Fig 32.1-1).
3. **Tornado Speed:** Compares the effective Tornado Speed ($V_T$) against the Basic Wind Speed ($V$).

If **Tornado Loads Required** calculates to "Yes", the calculator will generate a specific **Design Tornado Pressures** table alongside standard wind pressures.

<Note>
  **Want to learn more about tornado loads?** Check out our [Tornado Loads (ASCE 7-22) article](https://calcs.com/docs/calculators/us/wind-loads/tornado-loads) for detailed information on tornado load calculations and requirements.
</Note>

<img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-TORNADO-LOAD.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=a048decc570a1ba82ef2e6c5507c1ebb" width="550" alt="Wind Loads Tornado Load Parameters" style={{ width:"70%" }} data-path="images/WIND-TORNADO-LOAD.png" />

#### Calculations and Results

Once all properties are defined, the calculator determines the following parameters per ASCE 7-22:

* **Velocity Pressure** ($q_h$): based on wind speed, exposure, ground elevation factor ($K_e$), and topography ($K_{zt}$).
* **Internal Pressure Coefficient** ($GC_{pi}$): based on enclosure type. For **Partially Enclosed** buildings, the Internal Pressure Reduction Factor $R_i$ (Eq. 26.13-1) can be applied when the building is a single, unpartitioned large volume.
* **External Pressure Coefficients** ($GC_p$): based on effective wind area and zone (corner, edge, field).

## Method & scope

| Property         | Detail                                                                                                                            |
| ---------------- | --------------------------------------------------------------------------------------------------------------------------------- |
| Design standards | ASCE 7-22                                                                                                                         |
| Regions          | United States                                                                                                                     |
| Who it's for     | US structural engineers calculating wind loads to ASCE 7-22 for Components & Cladding and MWFRS.                                  |
| Presets          | Components and Cladding, MWFRS (Envelope Procedure), MWFRS (Directional Procedure)                                                |
| What it checks   | Site and building inputs, Velocity pressure, C\&C pressures (ASCE 7-22 Ch. 30), MWFRS pressures, Tornado loads (ASCE 7-22 Ch. 32) |

#### What it calculates

US structural engineers calculating wind loads to ASCE 7-22 for Components and Cladding and MWFRS. Covers velocity pressure, pressure coefficients, and design pressures for low-rise buildings, with override options for exposure, topography, and directionality.

Calculate wind pressures for both C\&C and MWFRS in one template, aligned to ASCE 7-22 and IBC 2024.

#### Calculation method

The Wind Loads (ASCE 7-22) calculator determines design wind pressures for low-rise buildings in the US per ASCE 7-22. It covers three distinct procedures in a single template: Components and Cladding (C\&C) per Chapter 30 Part 1 (Cl. 30.3), the MWFRS Envelope Procedure per Chapter 28, and the MWFRS Directional Procedure per Chapter 27.

##### Site and building inputs

Key inputs are:

* **Basic wind speed (V)**, from the ASCE 7-22 Figure 26.5-1 maps, or entered manually
* **Exposure category**, B, C, or D, which sets the velocity pressure exposure coefficient K\_z
* **Building dimensions**, roof mean height (h), least horizontal dimension (B\_min), and roof pitch (alpha)
* **Enclosure classification**, enclosed, partially enclosed, or open, which drives internal pressure coefficients (GCpi)
* **Topographic factor (K\_zt)**, computed from hill height, half-length, and site distance per ASCE 7-22 Cl. 26.8, or entered as 1.0 for flat terrain
* **Ground elevation factor (K\_e)**, based on elevation above sea level per ASCE 7-22

##### Velocity pressure

The design velocity pressure at height z is:

**q\_z = 0.00256 × K\_z × K\_zt × K\_d × K\_e × V²** (lb/ft², V in mph)

At mean roof height h, this becomes q\_h, which is the reference pressure for C\&C and MWFRS envelope calculations.

##### C\&C pressures (ASCE 7-22 Ch. 30)

External pressure coefficients (GCp) are looked up from ASCE 7-22 figures as a function of effective wind area and roof zone (zones 1, 2, 3 for roofs; zones 4 and 5 for walls). Net design pressure combines external and internal coefficients:

**p = q\_h × \[(GCp), (GCpi)]**

Zone widths a, 0.6h, and 0.2h are calculated automatically from building dimensions. Separate pressures are reported for roof and wall members for the effective areas entered.

##### MWFRS pressures

For the **Envelope Procedure** (Chapter 28), pseudo-lateral pressures on windward and leeward walls and roof zones are determined using simplified load cases A and B for both wind directions. For the **Directional Procedure** (Chapter 27), wall and roof pressure coefficients (Cp) are used with the velocity pressure at each height, and load cases 1 and 2 are applied. Overhang bottom-surface pressure is also calculated for both procedures.

##### Tornado loads (ASCE 7-22 Ch. 32)

If tornado speed (V\_T) is specified, tornado pressures are calculated and reported separately alongside wind pressures.

##### Assumptions and limitations

The calculator assumes no parapets (unless the parapet option is enabled), flat/gable/hip/monoslope roof geometry, and Cl. 26.2 low-rise building classification. The b-note reduction for pressure coefficients in the Directional Procedure is not applied. Results are tabulated by zone and load case, with each pressure linked to its governing ASCE 7-22 clause.

## How to use it

<Steps>
  <Step title="Zones Diagram">
    A dynamic diagram visualizes the zones on the roof and walls, helping you identify where specific pressures apply.

    <img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-DIAGRAM.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=612abb2bb8653d6089cb91c44bc90ee2" width="550" alt="Wind Loads Zones Diagram" style={{ width:"70%" }} data-path="images/WIND-DIAGRAM.png" />
  </Step>

  <Step title="Wind Pressure Results">
    The summary section provides a table listing the **Design Wind Pressures** for each zone.

    * **Zone:** Identifies the specific area (e.g., Zone 1, 2, 3 for roofs; 4, 5 for walls).
    * **Positive/Negative Pressure:** The design pressure ($p$) calculated as: $p = q_h [ (GC_p) - (GC_{pi}) ]$
    * **Minimum Loads:** ASCE 7-22 imposes a minimum wind pressure of **16 psf**. The calculator automatically compares calculated values and defaults to 16 psf if the calculated pressure is lower.

    <img src="https://mintcdn.com/clearcalcs/y4LgQ2d3nQV2ZtOG/images/WIND-FINAL-WIND-PRESSURES.png?fit=max&auto=format&n=y4LgQ2d3nQV2ZtOG&q=85&s=563bf73df52eaf4d1077c7dad8e5afa3" width="550" alt="Wind Loads Final Wind Pressures" style={{ width:"70%" }} data-path="images/WIND-FINAL-WIND-PRESSURES.png" />

    If Tornado Loads are applicable, a separate table **Design Tornado Pressures** will appear, displaying pressures ($p_T$) adjusted by the Tornado Directionality Factor ($K_{dT}$) and Tornado Pressure Coefficient Adjustment Factors ($K_{vT}$).
  </Step>

  <Step title="Strength-level pressures: no manual ASD conversion needed">
    <Note>
      Calcs.com uses the **same strength-level Components and Cladding wind pressure** in both **LRFD** and **ASD** member calculators. The ASD load combinations apply the **0.6W** factor internally, so you should enter the C\&C pressures **as-is regardless of which calculator you are working in**; do not manually multiply by 0.6 before entering them.
    </Note>

    Manual conversion only comes into play if you are bringing in **ASD or nominal wind values from outside Calcs.com** (for example, from a separate wind report already presented at ASD level). In that case, convert those external values back up to strength level before entering them, so the ASD combinations apply the 0.6W factor once and only once.

    For MWFRS Directional Procedure loads (Chapter 27), see [Wind Loads - MWFRS Directional Procedure (ASCE 7-16 and ASCE 7-22)](/docs/calculators/us/wind-loads/wind-loads-mwfrs-directional-asce-7-22).

    For parapet wind pressures on MWFRS or C\&C sheets, see [Wind Load Parapets (ASCE 7-16 and ASCE 7-22)](/docs/calculators/us/wind-loads/wind-loads-parapets-asce-7-22).

    | Preset                        | Preset code                        | App                                                                                                                                                                                                               |
    | ----------------------------- | ---------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
    | Components and Cladding       | `Components%20and%20Cladding`      | [Open](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=Components%20and%20Cladding)                                                                                                               |
    | MWFRS (Envelope Procedure)    | `MWFRS`                            | [Open](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=MWFRS)                                                                                                                                     |
    | MWFRS (Directional Procedure) | `MWFRS%20(Directional%20Procedure` | \[Open]\([https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=MWFRS%20(Directional%20Procedure)](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=MWFRS%20\(Directional%20Procedure\)) |
  </Step>
</Steps>

<iframe src="https://fast.wistia.net/embed/iframe/tzkh6eymd4?videoFoam=true" title="Wind Loads (ASCE 7-22) video walkthrough" className="w-full h-96 rounded-xl" allowFullScreen allow="autoplay; fullscreen" />

## Available presets

Each preset opens the calculator with a typical setup already entered.

| Preset                                                                      | Open in Calcs.com                                                                                                         |
| --------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------- |
| <span id="components-20and-20cladding" />Components and Cladding            | [Run with preset](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=Components%2520and%2520Cladding)        |
| <span id="MWFRS" />MWFRS (Envelope Procedure)                               | [Run with preset](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=MWFRS)                                  |
| <span id="mwfrs-20-directional-20procedure" />MWFRS (Directional Procedure) | [Run with preset](https://app.calcs.com/new/sheet/loadsWindCnCASCE7-22?presetCode=MWFRS%2520%28Directional%2520Procedure) |

## Common questions

<AccordionGroup>
  <Accordion title="What design standard does this calculator use?">
    The calculator follows ASCE 7-22 Chapter 26 through 30 for wind load determination on low-rise buildings. It applies the Envelope Procedure (Chapter 28) for MWFRS and Chapter 30 Part 1 for C\&C pressures. All velocity pressure and pressure coefficient references are cited directly on the output.
  </Accordion>

  <Accordion title="What are the key inputs?">
    Key inputs are basic wind speed (V) from the ASCE 7-22 Figure 26.5-1 maps, exposure category (B, C, or D), building mean roof height, roof slope, and enclosure classification (enclosed, partially enclosed, or open). Topographic factor (Kzt), directionality factor (Kd), and ground elevation factor (Ke) can be overridden for complex sites.
  </Accordion>

  <Accordion title="What does the calculator output?">
    Outputs include velocity pressure (qh and qz), MWFRS design pressures on each wall and roof zone, and C\&C design pressures on roof and wall components. Each pressure value is shown with the applicable GCp and GCpi coefficients, equation reference, and positive/negative sign convention per ASCE 7-22.
  </Accordion>

  <Accordion title="Does this cover both MWFRS and C&C in the same calculation?">
    Yes. The calculator handles both MWFRS (for lateral system design, shear walls, moment frames, diaphragms) and C\&C (for individual cladding elements, fasteners, and connections) in a single template. You do not need to run separate calculations for the two systems.
  </Accordion>

  <Accordion title="When should I use ASCE 7-22 versus ASCE 7-16 for wind loads?">
    Use ASCE 7-22 when your project is subject to IBC 2024 or when the authority having jurisdiction mandates the 2022 edition. ASCE 7-22 introduced updated wind speed maps with higher speeds in some hurricane-prone coastal regions compared to ASCE 7-16. For projects under IBC 2021, the ASCE 7-16 wind load calculator applies instead.
  </Accordion>
</AccordionGroup>

## Next steps

<CardGroup cols={2}>
  <Card title="US Snow Loads Calculator - Worked Example" icon="calculator" href="/docs/calculators/us/snow-loads/loadsSnowASCE7-16">
    Worked example: balanced, unbalanced and drift snow loads for sloped and flat roofs to ASCE 7-16 Chapter 7.
  </Card>

  <Card title="Worked Example: Seismic Analysis to ASCE 7-16" icon="calculator" href="/docs/calculators/us/seismic-loads/seismicAnalysisUS">
    Worked example: seismic design category, spectral accelerations, base shear and story forces to ASCE 7-16 with the equivalent lateral force procedure.
  </Card>

  <Card title="Tornado Loads (ASCE 7-22)" icon="calculator" href="/docs/calculators/us/wind-loads/tornado-loads">
    Calculate tornado loads for Components and Cladding and MWFRS (Directional Procedure) according to ASCE 7-22 Chapter 32.
  </Card>

  <Card title="Lateral Load Linking" icon="book" href="/docs/running-calculations/linking-loads/lateral-load-linking">
    Overview of the lateral load path workflow, from wind pressure through the diaphragm into the shear wall.
  </Card>

  <Card title="Wind Load Calculation Example for a Barn in Bernardsville, NJ" icon="calculator" href="/docs/running-calculations/example-calculations/us/wind-load-calculation-example-barn-bernardsville-nj">
    Worked example: MWFRS wind pressures on a barn in Bernardsville, NJ, with the ASCE 7-16 Envelope Procedure in the Wind Loads calculator.
  </Card>
</CardGroup>