AustraliaAS 3600:2018 (Amdt 2)
Concrete Development Length
Run the calcCalculate tension and compression development lengths for reinforcement to AS 3600:2018 (Amdt 2), with code references on every output. Handles hooked and straight bars, and applies the standard’s modification factors automatically.
Method & scope
Calculation method
The Concrete Development Length calculator computes tension and compression development lengths for reinforcing bars to AS 3600:2018 (Amendment 2), Section 13. It calculates both basic development lengths and refined development lengths, accounting for bar geometry, transverse reinforcement, cover, and stress conditions.Basic development length in tension (AS 3600:2018, Cl. 13.1.2.2)
The basic tensile development length L_sy,tb is the minimum length required for a straight bar to develop yield strength, assuming minimum cover and transverse reinforcement: L_sy,tb = k_1 × k_3 × f_sy × d_b / (k_2 × sqrt(f’c)) Where:- k_1, bar position factor (1.3 for top bars with more than 300mm concrete below, 1.0 otherwise)
- k_2, concrete density modification factor
- k_3, bar size factor: (132, d_b) / 100
Refined development length in tension (AS 3600:2018, Cl. 13.1.2.3)
The refined development length L_sy,t applies modification factors for transverse confinement and transverse compression: L_sy,t = k_rdl × L_sy,tb Where k_rdl combines factors k_4 (transverse confinement using the weighted average effectiveness factor lambda) and k_5 (transverse compression pressure factor). The transverse confinement factor lambda = (A_tr × n_f, 0.25 × d_b) / d_b accounts for the number and area of fitment legs. For bars that do not need to reach yield, a refined development length for unyielding bars L_st = max(sigma_st / f_sy × L_sy,t, 12 × d_b) is also reported.Development length in compression (AS 3600:2018, Cl. 13.1.5.3)
Basic compression development length L_sy,cb is the greater of:- 0.22 × f_sy × d_b / sqrt(f’c)
- 0.0435 × f_sy × d_b
Outputs
The calculator reports L_sy,tb, L_sy,t, L_st, L_sy,cb, L_sy,c, and L_sc. The maximum development length L_s,max across all conditions is also shown. All factor values and governing AS 3600:2018 clause references appear in the output.Assumptions
Reinforced concrete beam with yield strength limited to 65 MPa. Bundled bars are not used in tension. No multiplication factor for bends or standard hooks in compression is applied.How to use it
1
Open the calculator
Open it from Run calc in the About this calculator panel above.
2
Enter your inputs
Work through the input sections from top to bottom. Click any input label to see its reference explanation, clause, conditions and assumptions. See Checks, References, Conditions and Assumptions.
3
Review the results and export
Check the utilization of each governing check in the summary, then export a PDF report. See Views and Export.
Common questions
What design standard does this calculator use?
What design standard does this calculator use?
The calculator applies AS 3600:2018 incorporating Amendment 2 for development length calculations. It implements the provisions of AS 3600:2018 Section 13, Development and splices of reinforcement, including the basic development length formula and all applicable modification factors (k1 through k7).
What are the key inputs?
What are the key inputs?
Key inputs are concrete compressive strength (f’c), bar diameter and grade (N or L reinforcement), cover to the bar being developed, transverse reinforcement details (bar size and spacing), bar geometry (straight or standard hook), and application type (top bar, bottom bar, or compression). For hooked bars, the hook geometry and cover details are also required.
What does the calculator output?
What does the calculator output?
Outputs include the basic development length (Lsy.t or Lsy.c) and the final design development length after applying all applicable modification factors. For hooked bars, the development length to the back of the hook and the minimum embedment are also reported. All AS 3600:2018 clause references and factor values are shown in the output.
What modification factors does the calculator apply?
What modification factors does the calculator apply?
The calculator applies the AS 3600:2018 Section 13 modification factors: k1 (bar position, top bars with more than 300mm concrete below), k2 (concrete density), k3 (bar size and transverse reinforcement), k4 (transverse confinement pressure), and k5 (excess reinforcement). For compression bars, the equivalent compression factors are applied.
Can I use this calculator for lapped splices?
Can I use this calculator for lapped splices?
Development length is the basis for lap splice design per AS 3600:2018 Section 13.2.3. The design lap length is calculated as the development length multiplied by a factor for the proportion of bars spliced (1.0 for 50% or less spliced, 1.3 for more than 50%). Enter the development length from this calculator to determine the required lap length for your splice configuration.
Next steps
Australia & New Zealand Calculator Library
Complete list of Calcs.com design calculators available for Australian and New Zealand projects (AS 3600, AS 4100, AS 1720, AS/NZS 1170, and related standards).
Use the Concrete Pad Footing Calculator AS 3600:2018
Design concrete pad footings to AS 3600:2018 (Amdt 2) with instant moment, shear and punching shear results.
Development Length in Footings
Fix footings that fail development length checks: switch to plain concrete, adjust thickness, or develop the rebar.
Design a Concrete Column to AS3600:2018
Design rectangular and circular reinforced concrete columns to AS 3600:2018 (Amdt 2), with P-M interaction, biaxial bending, slenderness and shear.