steelBolt
Run the calcDesign and analyze bolt groups under shear, tension, and combined loading to AS 4100:1998. The elastic method distributes applied forces across the bolt group and checks shear, tensile, bearing, and friction limit states for the critical bolt.
This calculator uses an earlier code edition (AS4100:1998 (R2016)). It stays available for existing projects. For new designs, check the Calculator Library for the current edition.
Method & scope
Calculation method
The Steel Bolt (AS 4100:1998) calculator uses the elastic method to distribute applied loads across the bolt group and then checks each bolt and the governing ply against the strength and serviceability limit states in AS 4100 Clause 9.Load distribution
Applied forces (design shear V*, tensile force N*, in-plane moment M_z, and out-of-plane moment M_x) are resolved at the centroid of the bolt group. The centroid is calculated assuming uniform bolt area across all positions. For in-plane shear and moment, the elastic method distributes load to each bolt in proportion to its distance from the centroid using the polar moment of inertia I_z:- Direct shear per bolt = V* / n
- Torsional shear due to moment = M_z × r / I_z (where r is the distance of the bolt from the centroid)
- The horizontal and vertical components of torsional shear are resolved by the x and y coordinates of each bolt relative to the centroid
Bolt shear capacity (Clause 9.3.2)
The nominal shear capacity V_f per shear plane depends on the bolt tensile stress area and the location of the shear plane relative to the threads:- Threaded shear plane: V_f = 0.62 × f_uf × A_s
- Unthreaded shear plane: V_f = 0.62 × f_uf × A_o
Bolt tensile capacity (Clause 9.3.3)
Nominal tensile capacity N_tf = A_s × f_uf, giving design tensile capacity N_d,tf = phi_b × N_tf. Utilization = N*_tf / N_d,tf ≤ 1.0Combined shear and tension interaction (Clause 9.3.4)
For bolts loaded simultaneously in shear and tension, the circular interaction check is: Interaction ratio = (V_f / V_d,f)^2 + (N_tf / N_d,tf)^2 ≤ 1.0Ply bearing capacity (Clause 9.3.2)
Bearing failure in the connected ply is checked through two mechanisms:- Ply tearing (near edge): V_b,t = a_e × t_p × f_up
- Ply bearing (away from edge): V_b,b = 3.2 × d_f × t_p × f_up
Serviceability friction checks (Clause 9.3.3, friction bolts)
For high-strength bolts used in friction (8.8/TF category), the serviceability shear capacity accounts for clamping force and slip factor: V_d,sf = phi_b,f × V_sf The combined serviceability interaction for friction bolts under simultaneous shear and tension uses a linear interaction formula per the standard. Utilization = V*_sf / V_d,sf ≤ 1.0Capacity factors
- phi_b = 0.8 (bolt connections)
- phi_p = 0.9 (ply in bearing)
- phi_b,f = 0.7 (friction bolt serviceability)
How to use it
1
Open the calculator
Open it from Run calc in the About this calculator panel above.
2
Enter your inputs
Work through the input sections from top to bottom. Click any input label to see its reference explanation, clause, conditions and assumptions. See Checks, References, Conditions and Assumptions.
3
Review the results and export
Check the utilization of each governing check in the summary, then export a PDF report. See Views and Export.
Common questions
What design code does this calculator use?
What design code does this calculator use?
This calculator checks steel bolt connections to AS 4100:1998 (R2016). It covers bolt shear and tensile capacity, ply bearing, combined shear-and-tension interaction, and serviceability friction checks per Clause 9 of the standard.
What are the key inputs?
What are the key inputs?
Key inputs include the bolt category and size, number of shear planes with and without threads, ply thickness and tensile strength, applied design shear force, tensile force, in-plane moment, and out-of-plane moment on the bolt group. Serviceability inputs cover the slip factor and serviceability load factor for friction bolt checks.
What does the calculator output?
What does the calculator output?
Outputs include the design shear capacity per bolt (V_d,f), tensile capacity (N_d,tf), bearing capacity on the controlling ply (V_d,b), and the combined shear-and-tension interaction ratio. For friction bolt configurations, the serviceability shear capacity (V_d,sf) and combined serviceability interaction ratio are also reported.
Can it handle bolt groups under combined shear and tension?
Can it handle bolt groups under combined shear and tension?
Yes. For bolt groups with simultaneous shear and tension, the calculator evaluates the interaction ratio using the circular interaction formula: (V/V_d,f)^2 + (N/N_d,tf)^2 ≤ 1.0. The result is shown as a utilization ratio, values at or below 1.0 indicate a satisfactory design.
What bolt categories and sizes are supported?
What bolt categories and sizes are supported?
The calculator supports the bolt categories defined in AS 4100:1998, including 4.6/S, 8.8/S, 8.8/TB, and 8.8/TF categories, across standard metric bolt sizes. Bolt geometry (x and y coordinates) is entered as a table, so arbitrary group layouts are supported without restriction on the number of bolts.
Next steps
Calculator Library
Complete list of Calcs.com design calculators available for Australian and New Zealand projects (AS 3600, AS 4100, AS 1720, AS/NZS 1170, and related standards).
Design a Steel Bolt Connection to AS4100:2020
Design and analyze steel bolt connections to AS 4100:2020. Supports arbitrary bolt layouts with shear, tension, bearing, and friction serviceability checks.
Design a Weld Connection to AS 4100:2020
Analyze and design weld connections to AS 4100:2020, Cl 9.6. Checks fillet weld and butt weld capacity under combined shear and tension force per unit length.
Design a Weld Connection to AS 4100:1998
Design fillet and butt weld connections to AS 4100:1998 (R2016). An earlier code edition, kept for existing projects.
Design a Steel Beam to AS 4100:2020
Design steel beams to AS 4100:2020 with multiple supports and loads. Floor- and roof-beam presets cut repetitive entry.