Spread Footing (ACI 318-14)
Run the calcColumn loads link directly from the calculations above, so changes propagate to the footing automatically. Design isolated spread footings to ACI 318-14. Results cover bearing capacity under service loads, flexural design, one-way shear, two-way (punching) shear, and development lengths.
This calculator uses an earlier code edition (ACI 318-14). It stays available for existing projects. For new designs, check the Calculator Library for the current edition.
Method & scope
Calculation method
The Spread Footing (ACI 318-14) calculator designs isolated rectangular spread footings to ACI 318-14, with ASD and LRFD load combinations from ASCE 7-16 (Ch. 2). Service loads govern soil bearing and stability; factored loads govern the reinforced-concrete strength design. It handles concentric and eccentric (moment) loading and checks the full set of geotechnical and concrete limit states.Bearing pressure and stability
Service-level column loads are combined through the ASCE 7-16 ASD combinations and resolved into a soil bearing pressure profile under the footing. Under moment, an iterative procedure covers the partial-contact (Zone 2) eccentricity case where part of the footing lifts off the soil: utilization = q_max / q_allow ≤ 1.0 where q_allow is the allowable gross bearing capacity. Overturning and sliding are checked as factors of safety against user-set minimums: FS_overturning = M_resisting / M_overturning ≥ FS_min FS_sliding = (mu × N) / V ≥ FS_min both evaluated on the X and Y axes.Flexural capacity (ACI 318-14, Cl. 22.2)
Factored bending moments at the face of the column are computed on each axis and compared to the reduced flexural capacity of the reinforced section: utilization = M_u / (phi × M_n) ≤ 1.0 checked for X-axis and Y-axis bottom reinforcement. Where the bottom bars cannot develop, the calculator also evaluates whether a plain-concrete section passes. Negative bending (top reinforcement) capacity is checked on both axes for uplift or eccentric cases.One-way (beam) shear (ACI 318-14, Cl. 22.5)
One-way shear demand is taken at a distance d from the column face and compared to the concrete shear strength (no shear reinforcement is assumed): utilization = V_u / (phi × V_c) ≤ 1.0Two-way (punching) shear (ACI 318-14, Cl. 22.6)
Punching shear is checked on the critical perimeter located d/2 from the column face: utilization = v_u / (phi × v_c) ≤ 1.0 with v_c taken as the governing of the code expressions (aspect ratio, perimeter ratio, and the base term).Development of reinforcement (ACI 318-14, Cl. 25.4)
The required development length of the flexural bars is checked against the length available from the critical section to the bar end, applying the standard modification factors. Excess reinforcement area is credited to reduce the required length, and top-bar development is checked separately.Column-footing interface bearing (ACI 318-14, Cl. 22.8)
Bearing stress where the column lands on the footing is compared to the concrete bearing capacity, which is increased by the square root of the ratio of the supporting area to the loaded area (capped per code). Bearing dowels are sized where the interface bearing is exceeded.Assumptions
The column is centered on the footing and designed separately. Compression reinforcement is not counted in bending strength, and no shear reinforcement is considered. For steel base plates, only concrete bearing under concentric load is checked; eccentric (moment) interface bearing is verified separately. The column self-weight is not counted in the uplift check.How to use it
1
Open the calculator
Open it from Run calc in the About this calculator panel above.
2
Enter your inputs
Work through the input sections from top to bottom. Click any input label to see its reference explanation, clause, conditions and assumptions. See Checks, References, Conditions and Assumptions.
3
Review the results and export
Check the utilization of each governing check in the summary, then export a PDF report. See Views and Export.
Common questions
What design standard does this calculator use?
What design standard does this calculator use?
The calculator designs the concrete section to ACI 318-14, with ASD and LRFD load combinations from ASCE 7-16 (Ch. 2). Service-level loads govern soil bearing and stability; factored loads govern the reinforced-concrete strength checks (flexure, shear, and interface bearing).
What are the key inputs?
What are the key inputs?
Key inputs are footing width, length, and thickness, concrete strength and density, column width and length (or base plate dimensions) with any X and Y offset, allowable gross soil bearing capacity, depth and unit weight of soil over the footing, sliding friction coefficient, concrete cover, reinforcement yield strength and bar counts for each axis, and bearing dowels. Applied column loads (axial, moment, shear) can be entered manually or linked from a column calculation above.
What does the calculator check and output?
What does the calculator check and output?
It checks soil bearing pressure under service loads (including the partial-contact eccentric case), overturning and sliding factors of safety, flexural capacity at the column face on both axes, one-way (beam) shear, two-way (punching) shear, development of the flexural reinforcement, and concrete bearing at the column-footing interface. Demand, capacity, and utilization are reported for each check.
Can it handle moment (eccentric) loading and rectangular footings?
Can it handle moment (eccentric) loading and rectangular footings?
Yes. The calculator resolves axial load plus biaxial moment into a bearing pressure profile and runs an iterative procedure for the partial-contact (Zone 2) case where part of the footing lifts off the soil. Rectangular footings are supported, with reinforcement checked independently on the X and Y axes.
When does the footing need top reinforcement?
When does the footing need top reinforcement?
Top reinforcement is checked for negative bending, which can arise under uplift or large eccentric moments that reverse the bending on part of the footing. Enter top bar counts and spacing, and the calculator evaluates negative-bending flexural capacity and top-bar development on both axes alongside the bottom-reinforcement checks.
Does this calculator support load linking with column calculations?
Does this calculator support load linking with column calculations?
Yes. If a column calculation sits above the footing in the same Calcs.com project, the axial force, moment, and shear at the column base link directly. When the column loading, section, or height changes, the footing automatically re-runs bearing, flexure, one-way shear, punching shear, and interface bearing with the updated reactions, no manual re-entry.
Next steps
Calculator Library
Complete list of Calcs.com design calculators available for United States projects (AISC, ACI, NDS, ASCE 7, IBC, and related standards).
Design a Spread Footing (IBC 2024)
Design isolated spread footings to ACI 318-19 per IBC 2024 (ASCE 7-22): bearing, flexure, one-way and punching shear, and development length.
Design a Spread Footing (IBC 2021)
Design isolated spread footings to ACI 318-19 per IBC 2021 (ASCE 7-16). An earlier code edition, kept for existing projects.
Design a Combined Footing to ACI 318-19
Design combined rectangular footings for two columns to ACI 318-19 per IBC 2024: bearing, overturning, sliding, flexure, shear and development length.
Design a Wall Footing to ACI 318-14
Design continuous wall footings to ACI 318-14. An earlier code edition, kept for existing projects.
Concrete Spread Footings Under Biaxial Bending
How Calcs.com finds soil pressures on a spread footing under bending in both directions at once, and how to do the same by hand.
Spread Footing to ACI 318-14 - Validation Examples
Validation and design examples for concrete spread footings to ACI 318-14.