Steel Beam

NZS 3404.1:1997 (Amdt 2)Flag of New Zealand

Beam reactions link to the columns and footings below, so load changes propagate downstream automatically. Design steel beams to NZS 3404.1:1997 (Amdt 2) with multiple supports and loads. Checks cover section compactness, lateral torsional buckling, shear and bearing capacity, and short-term, long-term, and imposed-load deflections.

14-day free trial • No credit card required

  • NZS 3404.1:1997 (Amdt 2)

    Named standard on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 21 Sept 2026

    Version 63, latest calculation change

  • 660+ calculations

    In 2026 across 37 organizations

Start from your design scenario, not a generic setup

Each preset sets up this calculator for one design scenario, with the inputs that scenario usually takes already filled in. You change what differs on your project instead of re-entering every value on every job.

  • Generic Beam
  • Rafter
  • Roof Bearer
  • Underpurlin
  • Strutting / Counter-Strutting Beam
  • Verandah Beam
  • Hanging Beam
  • Ceiling Joist
  • Roof Lintel
  • Wind Beam
  • Floor Joist
  • Floor Bearer
  • Floor Lintel
  • Retaining Wall Sleeper

What it calculates

Beam reactions link to the columns and footings below, so load changes propagate downstream automatically. Design steel beams to NZS 3404.1:1997 (Amdt 2) with multiple supports and loads. Checks cover section compactness, lateral torsional buckling, shear and bearing capacity, and short-term, long-term, and imposed-load deflections.

Who uses this calculator

Beam reactions link to your column and footing calculations automatically - change a load once and everything downstream updates. Built for New Zealand structural engineers working to NZS 3404.1:1997 (Amdt 2), this calculator checks design moment capacity, shear capacity, bearing capacity, and three deflection limits across simple, continuous, and cantilevered spans.

How it calculates

Structural model

The calculator models the steel beam using a finite element method (FEM) engine. Supports are positioned at user-defined locations and can be pins or rollers. The solver produces moment, shear, deflection, and reaction diagrams for every load case and combination.

Load combinations (NZS 1170)

Loads are entered by type: permanent (G), imposed (Q), wind (W), and earthquake (E). The character of the imposed load (office, residential, storage, etc.) affects the combination factors psi. The calculator generates and evaluates all governing NZS strength and serviceability load cases, selecting the worst case for each check.

Section compactness (Clause 5.1 and 5.2)

Sections are classified by comparing flange and web element slenderness ratios to the yield and plastic limits from NZS 3404. Compactness classification (compact, non-compact, or slender) in bending about each axis determines the effective section modulus Z_e used in capacity calculations.

Design moment capacity (Clause 5.1 to 5.3)

Section moment capacity (phiM_s): computed from Z_e and yield stress, factored by phi.

Member moment capacity (phiM_bx): accounts for lateral torsional buckling using:

  • alpha_m: moment modification factor derived from the bending moment diagram at quarter-points (M2, M3, M4)
  • alpha_s: slenderness reduction factor, a function of the reference elastic buckling moment M_oa and the section moment capacity
  • Restraint classification per span (fully, partially, or laterally restrained)

Utilization: moment utilization = M*x / phiM_sx ≤ 1.0

Shear capacity (Clause 5.11)

The nominal shear yield capacity V_w and shear buckling capacity V_b are computed from web area A_w and the shear buckling coefficient alpha_v. The lesser governs. An additional check on the ratio of maximum to average shear stress (f_vm / f_va) is performed for non-uniform shear distributions.

Shear-moment interaction is checked where both V* and M* are significant at a cross-section.

Bearing capacity (Clause 5.13)

At each support, the bearing yield capacity and bearing buckling capacity are computed. The member slenderness reduction factor alpha_c accounts for web buckling under concentrated bearing. An additional bending-bearing interaction check is performed where required.

Deflection checks (Clause 2.3)

Three deflection types are checked against user-defined span/n limits:

  1. Short-term serviceability deflection - under short-term service loads
  2. Long-term serviceability deflection - including creep and shrinkage effects
  3. Imposed load deflection - live and imposed loads only

The governing deflection per span is extracted from the FEM solution and compared to the applicable limit. An optional absolute deflection limit (mm) can also be set.

Section properties

Properties (I_11, I_22, Z_11, S_11, S_22, J, I_w, A_g, A_w, alpha) are read from the built-in NZ/AU steel section database, including UB, UC, PFC, EA, UA, RHS, SHS, and CHS sections. The angle of the major principal axis and the centroid location are used to resolve loads for asymmetric sections.

Load linking

Support reactions are exported as linked outputs. Column and footing calculations placed downstream automatically receive the updated reactions when beam inputs change.

What engineers say

Engineer
Ward Engineering

“The biggest thing I noticed about Calcs.com that made me a believer was the load linking. That was a game-changer.”

Matt Ward

Principal Engineer, Ward Engineering

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.