We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.

Calcs.com
NZS 3404.1:1997 (Amdt 2)New Zealand

Steel Beam

Beam reactions link to your column and footing calculations automatically - change a load once and everything downstream updates. Built for New Zealand structural engineers working to NZS 3404.1:1997 (Amdt 2), this calculator checks design moment capacity, shear capacity, bearing capacity, and three deflection limits across simple, continuous, and cantilevered spans.

Start free trial

14-day free trial - no credit card required

What it calculates

Beam reactions link to the columns and footings below, so load changes propagate downstream automatically. Design steel beams to NZS 3404.1:1997 (Amdt 2) with multiple supports and loads. Checks cover section compactness, lateral torsional buckling, shear and bearing capacity, and short-term, long-term, and imposed-load deflections.

Code standards

  • NZS 3404.1:1997 (Amdt 2)

How it calculates

Structural model

The calculator models the steel beam using a finite element method (FEM) engine. Supports are positioned at user-defined locations and can be pins or rollers. The solver produces moment, shear, deflection, and reaction diagrams for every load case and combination.

Load combinations (NZS 1170)

Loads are entered by type: permanent (G), imposed (Q), wind (W), and earthquake (E). The character of the imposed load (office, residential, storage, etc.) affects the combination factors psi. The calculator generates and evaluates all governing NZS strength and serviceability load cases, selecting the worst case for each check.

Section compactness (Clause 5.1 and 5.2)

Sections are classified by comparing flange and web element slenderness ratios to the yield and plastic limits from NZS 3404. Compactness classification (compact, non-compact, or slender) in bending about each axis determines the effective section modulus Z_e used in capacity calculations.

Design moment capacity (Clause 5.1 to 5.3)

Section moment capacity (phiM_s): computed from Z_e and yield stress, factored by phi.

Member moment capacity (phiM_bx): accounts for lateral torsional buckling using:

  • alpha_m: moment modification factor derived from the bending moment diagram at quarter-points (M2, M3, M4)
  • alpha_s: slenderness reduction factor, a function of the reference elastic buckling moment M_oa and the section moment capacity
  • Restraint classification per span (fully, partially, or laterally restrained)

Utilization: moment utilization = M*x / phiM_sx ≤ 1.0

Shear capacity (Clause 5.11)

The nominal shear yield capacity V_w and shear buckling capacity V_b are computed from web area A_w and the shear buckling coefficient alpha_v. The lesser governs. An additional check on the ratio of maximum to average shear stress (f_vm / f_va) is performed for non-uniform shear distributions.

Shear-moment interaction is checked where both V* and M* are significant at a cross-section.

Bearing capacity (Clause 5.13)

At each support, the bearing yield capacity and bearing buckling capacity are computed. The member slenderness reduction factor alpha_c accounts for web buckling under concentrated bearing. An additional bending-bearing interaction check is performed where required.

Deflection checks (Clause 2.3)

Three deflection types are checked against user-defined span/n limits:

  1. Short-term serviceability deflection - under short-term service loads
  2. Long-term serviceability deflection - including creep and shrinkage effects
  3. Imposed load deflection - live and imposed loads only

The governing deflection per span is extracted from the FEM solution and compared to the applicable limit. An optional absolute deflection limit (mm) can also be set.

Section properties

Properties (I_11, I_22, Z_11, S_11, S_22, J, I_w, A_g, A_w, alpha) are read from the built-in NZ/AU steel section database, including UB, UC, PFC, EA, UA, RHS, SHS, and CHS sections. The angle of the major principal axis and the centroid location are used to resolve loads for asymmetric sections.

Load linking

Support reactions are exported as linked outputs. Column and footing calculations placed downstream automatically receive the updated reactions when beam inputs change.

What engineers say

Matt Ward company logo
The biggest thing I noticed about Calcs.com that made me a believer was the load linking. That was a game-changer.

Matt Ward

Principal Engineer, Ward Engineering

Frequently asked questions

What design code does this calculator use?
The calculator designs steel beams to NZS 3404.1:1997 (Amdt 2) using the limit states design method. Load combinations follow NZS 1170.0 and NZS 1170.1 as applicable. Both strength and serviceability limit states are checked.
What are the key inputs?
Key inputs include the steel section and steel type, total beam length, lateral restraint type and maximum spacing at the critical flange, support positions, distributed and point loads by load type (G, Q, W, E), height of load application relative to the shear centre, and deflection limit criteria per span.
What checks and outputs does it produce?
The calculator produces: design moment demand M*x vs. design member moment capacity phiM_sx (including lateral torsional buckling via alpha_m and alpha_s), design shear demand V* vs. capacity phiV_vn, bearing demand R* vs. capacity phiR_b at each support, shear-moment interaction, bending-bearing interaction, and short-term, long-term, and imposed-load deflection ratios.
How does the calculator handle lateral torsional buckling?
The calculator classifies each span's end restraints using the NZS 3404 segment classification table. It then computes the moment modification factor alpha_m from the bending moment distribution and the slenderness reduction factor alpha_s from the reference buckling moment. The member moment capacity accounts for both cross-section compactness and LTB.
Can it check biaxial bending?
Yes. For sections loaded at an angle to the principal axes (such as equal and unequal angles), the calculator resolves loads into major and minor axis components and checks biaxial moment utilization.
Does this calculator support load linking with column and footing calculations?
Yes - beam reactions link directly to connected column and footing calculations. When inputs change, all downstream calcs update automatically.