Timber Bolt
Design timber bolted connections to AS 1720.1:2010 - shear capacity, in-plane moment, and tension checks for bolt patterns in Australian timber construction.
14-day free trial - no credit card required
What it calculates
Easily design and analyse timber bolt connections with the Calcs.com Timber Bolt Calculator to AS 1720.1:2010. The calculator assumes bolt patterns subject to direct shear, in-plane moment, or tension. Detailing requirements including clause 4.4.4 modifications are to be checked separately.
Code standards
- AS 1720.1:2010
Who uses this calculator
Design timber bolted connections to AS 1720.1:2010 - shear capacity, in-plane moment, and tension checks for bolt patterns in Australian timber construction.
Bolted connections transfer high loads between heavy timber members in post-and-beam frames, glulam portals, and engineered wood structures. Under-designed bolt patterns can lead to timber splitting, fastener shear failure, or group-action overload - all of which are difficult to detect visually after construction. Getting the characteristic capacity, the k17 group factor, and the washer bearing area right from the outset avoids costly rework and keeps the design traceable to AS 1720.1.
How it calculates
The Timber Bolt calculator follows the design procedure in AS 1720.1:2010 Section 4.4 to determine the capacity of a bolted timber connection under lateral shear, direct tension, or combined loading.
Characteristic bolt capacity
For a single bolt loaded laterally (Type 1 joint), the characteristic capacity Qsk depends on the load angle relative to the grain:
- Parallel to grain: Qsk = Qsk1, taken from AS 1720.1 Table 4.9(A) based on bolt diameter and effective timber thickness
- Perpendicular to grain: Qsk = Qskp, taken from AS 1720.1 Table 4.10(A)
- At angle θ to grain: Qsk = (Qsk1 × Qskp) / (Qsk1 × sin²θ + Qskp × cos²θ)
The system capacity parameters that modify Qsk1 and Qskp for multi-ply arrangements are drawn from Tables 4.9(B-C) and 4.10(B-C).
For bolts loaded in direct tension (Type 2 joint), the maximum tensile capacity per bolt N_d,tb is taken from Table 4.11 based on bolt diameter and material grade.
Design capacity - Type 1 joint (shear)
The design capacity of the bolt group in lateral shear is:
N_d,j = φ × k1 × k16 × k17 × n × Qsk
Where:
- φ = capacity reduction factor from Clause 2.3 (0.6 for most bolted connections)
- k1 = duration of load factor for joints from Clause 2.4.1.1 (0.57 for permanent load, up to 1.14 for wind/earthquake)
- k16 = 1.2 when bolts transfer load through close-fitting holes into steel side plates; 1.0 otherwise
- k17 = group factor from Table 4.12, which reduces capacity for bolt rows with more than 4 bolts parallel to the grain
- n = number of bolts in the group resisting the design action effect in shear
The design action effect must satisfy N* ≤ N_d,j.
Design capacity - Type 2 joint (tension)
For bolts loaded in direct tension, the group capacity is:
N_d,j = φ × k1 × k7 × n × f'_pj × Aw
Where:
- k7 = length of bearing factor from Table 2.6
- f'_pj = characteristic bearing capacity for timber at joint details, from Table C6
- Aw = effective washer bearing area from Table 4.11
This check ensures the washer and timber bearing surface can transfer the tensile load without pull-through.
Combined shear and tension
When load acts at an angle to the bolt axis, both Type 1 (shear component normal to bolt axis) and Type 2 (tension component parallel to bolt axis) capacity checks are applied simultaneously per Clause 4.4.3.4. Both utilization ratios must be at or below 1.0.
Load distribution in bolt groups
For bolt groups subject to concentric direct loads, the applied force is divided equally across all n bolts. The calculator does not automatically redistribute load for eccentric patterns - eccentricity effects per Clause 4.4.6 must be assessed separately.
Washer requirements
Every bolt in a timber-to-timber bolted joint requires a washer at each end per Clause 4.4.5. The minimum washer size is governed by bolt diameter as specified in Table 4.11. The effective bearing area Aw of the washer directly enters the Type 2 tension check.
Capacity factors
- φ = 0.6 for bolted connections (Clause 2.3)
- k1 ranges from 0.57 (permanent load) to 1.14 (wind and earthquake, short duration)
- k17 = 1.0 for up to 4 bolts in a row parallel to grain; reduces progressively for larger groups per Table 4.12
Frequently asked questions
What design standard does this calculator use?
What are the key inputs?
What does the calculator check and output?
Can I account for eccentric loading?
When should I use a bolt instead of nails or screws?
Access this calculator and 100+ more
All verified, standards-aligned. Start a free trial - no credit card required.