Cold-Formed Steel Stud / Column

AISI S100-16(2020) w/S2-20Flag of United States

Design cold-formed steel studs and columns to AISI S100-16(2020) with independently specified strong-axis, weak-axis, and torsional effective lengths. Checks cover local, distortional, and global buckling via the Direct Strength Method, with optional lateral loads for bending, shear and combined checks. Axial load reactions link to connected beam and footing calculations so changes propagate automatically.

14-day free trial • No credit card required

  • AISI S100-16(2020) w/S2-20

    Named standard on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 24 Aug 2026

    Version 69, latest calculation change

  • 700+ calculations

    In 2026 across 260+ organizations

What it calculates

Design cold-formed steel studs and columns to AISI S100-16(2020) with independently specified strong-axis, weak-axis, and torsional effective lengths. Checks cover local, distortional, and global buckling via the Direct Strength Method, with optional lateral loads for bending, shear and combined checks. Axial load reactions link to connected beam and footing calculations so changes propagate automatically.

Who uses this calculator

Axial load reactions from beams above link directly to this calculation and update automatically when any upstream input changes. Design cold-formed steel studs and columns to AISI S100-16(2020) with separate strong-axis, weak-axis, and torsional effective lengths. Axial checks cover local, distortional, and global buckling via the Direct Strength Method. Add lateral loads and it also checks bending, shear, combined actions and deflection.

How it calculates

The Cold-Formed Steel Column calculator designs CFS studs and columns to AISI S100-16(2020) using the Direct Strength Method (DSM) for axial capacity. Axial loads are assumed concentric, and lateral loads are optional. LRFD load combinations from ASCE 7/IBC determine the governing factored axial demand Pu.

DSM axial capacity

The nominal axial capacity is governed by the minimum of three limit states:

Global buckling - φPne: Critical elastic buckling loads are computed from the effective slenderness ratios KxLx/rx (strong axis), KyLy/ry (weak axis), and torsional slenderness about the shear center (using section properties Xo, Yo - distance from centroid to shear center). The least elastic buckling load governs, and the DSM global buckling equations convert this to the nominal global capacity Pne.

Local buckling - φPnl: Critical local buckling load Pncrl is determined from the section geometry. The DSM local-global interaction equations per AISI S100-16 Section C3.1 give the local buckling capacity relative to Pne:

Pnl = DSM_local(Pne, Pncrl)

Distortional buckling - φPnd: The characteristic distortional buckling load Pncrd is derived from the section's distortional buckling mode. The DSM distortional column equations give Pnd independently of the global buckling result.

The governing capacity is:

φPn = min(φPnl, φPnd, φPne)

and the utilization check is Pu / φPn ≤ 1.0 where φ = 0.85.

Lateral loads: bending, shear and deflection

Lateral loads can be point loads, moments or distributed loads. The design wind and seismic pressures, times their tributary widths, set the default rows of the Lateral Distributed Loads table. When any lateral load is present, the column is analyzed as a cantilever, fixed at the base and free at the top.

The calculator then checks:

  • Bending: φMn = 0.90 × Mn against positive and negative moment, with Mn the least of the global, local and distortional buckling strengths
  • Shear: φVn = 0.95 × Vn against the maximum shear
  • Combined axial and bending: Pu/φPn + B2 × Mu/φMn ≤ 1.0 (AISI S100-16, Eqn H1.2-1)
  • Combined bending and shear at the support (AISI S100-16, Section H2)
  • Deflection against the lesser of the absolute limit and the height divided by the span ratio

The sway amplifier is B2 = 1 / (1 − Pu/Pe,story), with Pe,story = π²EI/(2L)² for the cantilever. The check fails if Pu reaches Pe,story.

The calculator does not check the ratio of second-order to first-order drift. Its Lengths table recommends K = 2.1 for buckling in the plane of the lateral load. A seismic pressure only reaches the analysis through an Eh row in the Lateral Distributed Loads table, and the calculator flags a missing row. Net uplift on the column is not supported.

What engineers say

Engineer

“Calcs.com simplified my beam analysis. It made structural checks easy and impressively fast. I first heard about Calcs.com while looking for alternatives to StruCalc, checked out a few options, and went with Calcs.com for simple residential beam analysis. The reports are strong, especially the one-page summary. I've also gotten used to linking beams within a project, which is handy for changing load scenarios and having that flow through other members. Over the years, Calcs.com has been responsive to feedback and requests, and the product continues to help me work through structural analysis faster than anything else I've used.”

Aaron D. Obermiller, P.E.

Engineer, REO Engineering

Engineer

“The wood and steel beam calculators are delightful. I especially like selecting the wood species for my beam and Calcs.com automatically loading all of the relevant material properties so I don't need to look them up in the NDS.”

John Cagle

Project Engineer, CHM Engineering

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.