What it calculates
The Calcs.com timber column calculator to CSA O86 enables the fast and accurate design of wood columns and studs to Canadian standards. With support for dynamic load linking between beams and columns, easily design accurate and quality engineered columns.
Who uses this calculator
Column loads link from beam reactions above to footing calculations below automatically - change a load once and everything downstream updates. Design wood columns and studs to CSA O86:19 with NBCC 2015 load combinations: axial compressive resistance, combined bending plus axial interaction, biaxial buckling, shear, and bearing perpendicular to grain.
How it calculates
Structural model and load combinations
The calculator models the wood column as a member under combined axial compression and biaxial bending. Loads are entered by type - dead (D), live (L), snow (S), wind (W) - and the calculator generates all governing NBCC 2015 / CSA O86:19 strength load combinations. Bending moments can be entered directly or received via load linking from beam calculations above.
Axial compressive resistance (CSA O86:19 Cl.6.5.5.2.4)
Factored compressive resistance P_r is computed from the characteristic compressive strength F_c parallel to grain, adjusted by:
- K_H - system factor
- K_Scp - service-condition factor for compression
- K_T - treatment factor
- K_c - slenderness factor, derived from the slenderness ratio C_c for each axis
The slenderness ratio C_c is computed for both the X-axis and Y-axis independently per Cl.6.5.5.2.2. The governing (largest) ratio controls the slenderness factor K_c, reducing compressive resistance for slender members. For multi-ply columns, Cl.6.5.5.4 applies additional reduction factors based on the ply connection method.
compression utilization = P_f / P_r ≤ 1.0
Bending moment resistance (CSA O86:19 Cl.6.5.3.1 and Cl.7.5.6.5.1)
Factored bending resistance M_r is computed for both the X-axis and Y-axis using adjusted bending strength F_b. The lateral stability factor (Cl.7.5.6.5.1) accounts for buckling of the compression face and is applied independently for each axis.
Combined bending and axial interaction (CSA O86:19 Cl.7.5.12)
When both axial compression and bending moments are present, the calculator checks the biaxial interaction equation per CSA O86:19 Cl.7.5.12, using the formulation from AWC Technical Report 14:
interaction utilization = P_f/P_r + M_fx/M_rx + M_fy/M_ry ≤ 1.0
Where M_fx and M_fy are the factored bending moments about the strong and weak axes respectively. This single interaction check governs over the individual axial and bending utilizations when moments are present.
Shear resistance (CSA O86:19 Cl.6.5.4.3)
Shear resistance is checked independently for forces applied in each direction, using the same adjustment factors applied to the bending checks.
Bearing perpendicular to grain (CSA O86:19 Cl.6.5.6.2)
Bearing is an optional check at the column base, assuming the bottom plate is the same species and grade as the column. Factored bearing resistance Q_r is computed from the compressive strength perpendicular to grain over the bearing area. The strength is adjusted for load duration, service condition and treatment. Bearing at point loads is not considered, and the bearing check does not set the column's governing utilization.
Load linking
The column's axial reaction at its base is exported as a linked output to connected footing calculations. Axial load at the top can be linked from beam reactions above, so the full load path - beam to column to footing - updates automatically when any upstream input changes.