Wood Member (Design Only - ASD, NDS 2018)

NDS 2024Design Only - ASDFlag of United States

The Calcs.com timber Member ASD calculator to NDS 2018 enables the fast and accurate design of wood members that can be used to design trusses and frames to American standards.

14-day free trial • No credit card required

  • NDS 2018 (ASD)

    Named standard on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 20 Feb 2026

    Version 18, latest calculation change

  • 210+ calculations

    In 2026 across 50 organizations

Start from your design scenario, not a generic setup

Each preset sets up this calculator for one design scenario, with the inputs that scenario usually takes already filled in. You change what differs on your project instead of re-entering every value on every job.

  • Manual Input
  • Link to Analysis Module

What it calculates

The Calcs.com timber Member ASD calculator to NDS 2018 enables the fast and accurate design of wood members that can be used to design trusses and frames to American standards.

Who uses this calculator

Built for engineers designing truss chords and frame members under combined axial and bending loading to NDS 2018 ASD. This is the legacy NDS 2018 version - use the NDS 2024 version for new work. If you need to maintain or peer-review projects originally designed to NDS 2018, this calculator provides the full combined loading interaction checks without requiring a switch to the updated standard.

How it calculates

Design method

This calculator uses Allowable Stress Design (ASD) per the AWC National Design Specification for Wood Construction, 2018 edition (NDS 2018). Unlike the Wood Beam or Wood Column calculators - which are purpose-built for single load-path elements - this design-only calculator accepts any combination of axial force and bending moment as direct inputs or via a linked Analysis Module element. It is the standard tool for checking truss chords and frame members where combined loading governs.

Only sawn lumber sections are supported in this version, and only strong-axis (X-X) bending is evaluated for combined loading.

Column stability factor

The column stability factor CP controls the allowable compression stress and is computed independently for each principal axis:

FcE = 0.822 × E'min / (Le / d)²

Where Le is the effective column length for the axis being checked and d is the corresponding cross-section dimension. A separate slenderness ratio and FcE is calculated for each axis. The governing (lower) FcE is used in the combined interaction equation.

CP is then found from NDS Eq. 3.7-1:

CP = (1 + FcE / Fc) / (2c) - sqrt[((1 + FcE / Fc) / (2c))² - FcE / (F*c × c)]

Where c = 0.8 for sawn lumber and F*c = Fc × CD × CM × Ct × CF × Ci (all factors except CP).

Individual stress checks

Before evaluating the interaction equations, each stress component is checked individually:

Compression: fc / F'c ≤ 1.0, where F'c = Fc × CD × CM × Ct × CF × Ci × CP

Tension: ft / F't ≤ 1.0, where F't = Ft × CD × CM × Ct × CF × Ci

Bending: fb / F'b ≤ 1.0, where F'b = Fb × CD × CM × Ct × CF × Ci × CL × Cr

The beam stability factor CL accounts for lateral-torsional buckling; for members with continuous bracing on the compression edge, CL = 1.0.

Shear: fv / F'v ≤ 1.0, where F'v = Fv × CD × CM × Ct × Ci

Combined axial compression and bending interaction

For members under simultaneous compression and bending - the governing case for most truss chords and frame rafter members - the calculator evaluates NDS 2018 Eq. 3.9-3 for strong-axis bending:

(fc / F'c)² + fb,x / (F'b,x × [1 - fc / FcE,x]) ≤ 1.0

If biaxial bending is also present, the full NDS Eq. 3.9-4 is applied:

(fc / F'c)² + fb,x / (F'b,x × [1 - fc / FcE,x]) + fb,y / (F'b,y × [1 - fc / FcE,y - (fb,x / FbE)²]) ≤ 1.0

Where FbE = 1.20 × E'min / RB² is the critical buckling stress for lateral-torsional buckling.

Combined tension and bending interaction

For truss bottom chords and other tension members with simultaneous bending, NDS 2018 Eq. 3.9-1 governs:

ft / F't + fb / F'b ≤ 1.0

NDS Eq. 3.9-2 provides a complementary check at the extreme fiber for the combined stress state.

Assumptions and scope

The calculator assumes members are straight, prismatic (not tapered), and not notched. For built-up members where multiple plies increase the depth beyond the width, the strong and weak axes refer to the axes of individual plies rather than the composite section. Only sawn lumber is supported - engineered lumber (LVL, PSL, LSL) and glulam require the appropriate section properties and different reference values.

Tested against worked examples

Each case shown is a worked example the calculator has been tested and verified against.

Example E1.6: combined bending and tension

American Wood Council, Structural Wood Design Examples

Standard or design guide

Example E1.7: combined bending and compression

American Wood Council, Structural Wood Design Examples

Standard or design guide

Example 4.2: bending member, full lateral-torsional buckling

Aghayere and Vigil, Structural Wood Design

Textbook

Example 4.2: shear check

Aghayere and Vigil, Structural Wood Design

Textbook

Example 5.1: sawn lumber tension member

Aghayere and Vigil, Structural Wood Design

Textbook

Example 5.3: tension member

Aghayere and Vigil, Structural Wood Design

Textbook

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached