Timber Beam

EN 1995-1-1:2004+A1:2008 (Eurocode 5)EN 1990:2002

The easy to use online Calcs.com Timber Beam Calculator for Eurocode enables you to do quick and powerful design and analysis for simple and continuous timber beams, with unlimited supports and loads. Easily create your own timber section dimensions and get instant results with our easy to understand traffic light checks for moment, deflection, and shear.

14-day free trial • No credit card required

  • EN 1995-1-1:2004+A1:2008 (Eurocode 5), EN 1990:2002

    Named standards on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 21 Jul 2026

    Version 55, latest calculation change

  • 460+ calculations

    In 2026 across 210+ organizations

Start from a preset

Pick the member closest to yours. Choose it when the calculator opens and its values load in.

What it calculates

The easy to use online Calcs.com Timber Beam Calculator for Eurocode enables you to do quick and powerful design and analysis for simple and continuous timber beams, with unlimited supports and loads. Easily create your own timber section dimensions and get instant results with our easy to understand traffic light checks for moment, deflection, and shear.

Who uses this calculator

Beam reactions link to your column and footing calculations automatically - change a load once and everything downstream updates. Design timber beams to Eurocode 5 (EN 1995-1-1:2004) using custom cross-section dimensions, with checks for bending, lateral torsional buckling, shear, bearing, and instantaneous plus final deformation.

How it calculates

Structural model and load combinations

The calculator models the timber beam as a one-dimensional element and computes bending moment, shear, and deflection diagrams under each EN 1990:2002 load combination. Loads are entered by type - permanent (G), variable (Q), wind (W), snow (S) - and the calculator generates governing ultimate limit state (ULS) and serviceability limit state (SLS) combinations. Two deformation combinations are generated: instantaneous (characteristic combination) and final (accounting for creep via k_def).

Material partial factor and k_mod

Characteristic strengths from the strength class (or custom input) are divided by the material partial factor gamma_M per EN 1995-1-1:2004 Cl 2.4.1 Table 2.3 (or the relevant National Annex). The resulting design strength is then multiplied by the modification factor k_mod, which accounts for service class (1, 2, or 3) and the governing load duration class (permanent through instantaneous) within each combination.

design strength = f_k × k_mod / gamma_M

Bending strength (EN 1995-1-1:2004 Cl 6.1.6)

The design bending stress sigma_m,d is computed from the applied bending moment and the elastic section modulus W_y = b × d² / 6. The allowable bending strength f_m,d is derived from the characteristic bending strength adjusted by k_mod and gamma_M. For members with multiple plies, the group modification factor is applied.

bending utilization = sigma_m,d / f_m,d ≤ 1.0

Lateral torsional buckling (EN 1995-1-1:2004 Cl 6.3.3)

When the compression edge of the beam is not fully laterally restrained, the calculator checks lateral torsional buckling. The relative slenderness for bending lambda_rel,m is computed from the critical bending stress sigma_m,crit. Where lambda_rel,m exceeds 0.75, a stability factor k_crit is applied:

reduced bending utilization = sigma_m,d / (k_crit × f_m,d) ≤ 1.0

Shear strength

Design shear stress tau_d is computed from the maximum shear force and the cross-section area (b × d). It is checked against the design shear strength f_v,d = f_v,k × k_mod / gamma_M.

shear utilization = tau_d / f_v,d ≤ 1.0

Bearing strength (EN 1995-1-1:2004 Cl 6.1.5)

At each support, compressive stress perpendicular to grain sigma_c,90,d is checked against the design compressive strength perpendicular to grain f_c,90,d, modified by a factor k_c,90 that accounts for the support length and configuration.

bearing utilization = sigma_c,90,d / (k_c,90 × f_c,90,d) ≤ 1.0

Deformation checks (EN 1995-1-1:2004 Cl 2.2.3 and Table 7.2)

Instantaneous deformation u_inst is computed under the characteristic serviceability combination using the mean modulus of elasticity E_mean. Final deformation u_fin includes creep, computed using the effective modulus E_mean / (1 + k_def), where k_def is a creep factor that depends on service class and load duration.

Both are checked against span-ratio limits from EN 1995-1-1:2004 Table 7.2 (or National Annex values), and against an optional user-defined absolute limit in mm.

Load linking

Support reactions are exported as linked outputs. Connected column and footing calculations placed downstream in the same project receive updated reactions automatically whenever the beam inputs change.

What engineers say

Engineer

“Calcs.com simplified my beam analysis. It made structural checks easy and impressively fast. I went with Calcs.com for simple residential beam analysis. The reports are strong, especially the one-page summary. I've also gotten used to linking beams within a project, which is handy for changing load scenarios and having that flow through other members.”

Aaron D. Obermiller, P.E.

Engineer, REO Engineering

Engineer

“All the calculators are much more user friendly than other programs I have used in the past. The wood and steel beam calculators are delightful. I especially like selecting the wood species for my beam and Calcs.com automatically loading all of the relevant material properties so I don't need to look them up.”

John Cagle

Project Engineer, CHM Engineering

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.