Eccentrically Loaded Bolt Group, ICR Method (CSA S16-19)

CSA S16-19CISC Handbook of Steel Construction (12th ed.), Part 3Flag of Canada

Find the eccentric bolt-group coefficient C by the instantaneous center of rotation method for any load angle, then the group shear resistance from the CSA S16-19 bolt shear resistance. Every bolt's force, direction and deformation is shown, so the C value can be checked rather than read off a table.

14-day free trial • No credit card required

  • CSA S16-19, CISC Handbook of Steel Construction (12th ed.), Part 3

    Named standards on every check

  • Clause on every result

    Formula, inputs and reference visible

What it calculates

Find the eccentric bolt-group coefficient C by the instantaneous center of rotation method for any load angle, then the group shear resistance from the CSA S16-19 bolt shear resistance. Every bolt's force, direction and deformation is shown, so the C value can be checked rather than read off a table.

Who uses this calculator

Engineers in Canada checking a bolt group loaded off its centroid, when the load angle or pattern is not covered by the CISC Handbook coefficient tables. Every bolt's force and deformation is reported, so coefficient C can be checked instead of interpolated. Rectangular bolt grids with uniform pitch and gage.

How it calculates

The calculator finds coefficient C for a rectangular bolt group under an eccentric load, then multiplies it by the factored shear resistance of one bolt to get the shear capacity of the group.

Bolt group and loading

You define a rectangular grid by its number of rows and columns, the vertical pitch and the horizontal gage. Bolt coordinates are measured in millimeters from the group centroid. The factored shear V_f and axial force H_f each act at their own eccentricity, and together they set the resultant force R_f and the load angle measured from the shear axis. The shear force must be non-zero for the ICR solution.

Instantaneous center of rotation

Under an eccentric load, the bolt group rotates about an instantaneous center. Each bolt deforms in proportion to its distance from that center, normalized by the bolt furthest away, which reaches the ultimate deformation of 8.6 mm (0.34 in). This is the value underlying the CISC Handbook coefficient tables. Bolt force acts perpendicular to the line from the instantaneous center to the bolt.

The location of the instantaneous center (y_o, r_o) is solved in the sheet with a two-unknown Newton-Raphson iteration on the moment and force equilibrium equations. This covers both pure shear and combined shear and axial loading.

Coefficient C is the resultant bolt force from the solved distribution, expressed as a multiple of the single-bolt resistance.

Bolt shear resistance

The single-bolt factored shear resistance V_r follows CSA S16-19 Clause 13.12.1.2(c). It uses the bolt resistance factor φ_b, the number of shear planes, the bolt area from the nominal diameter, and the ultimate tensile strength of the selected grade. A thread factor of 0.70 applies when threads are included in the shear plane, and 1.0 when they are excluded. The shear factor is 0.60, reduced to 0.50 when the lap length exceeds 760 mm.

Group capacity check

Bolt group shear capacity P_r = C × V_r

Demand capacity ratio = R_f / P_r ≤ 1.0

The concentric group resistance, V_r times the number of bolts, is reported as an upper bound.

Per-bolt results

A results table lists every bolt's position, radius from the instantaneous center, deformation, force ratio, force magnitude, components and direction. The table and the force diagram read the same distribution that produces C, so the coefficient can be traced bolt by bolt.

Validation and scope

The calculator is checked against coefficient values from CISC Handbook Tables 3-14, 3-15 and 3-20. Bearing on the connected plies is not checked, and irregular bolt patterns are not supported.

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.