Snow Loads (ASCE 7-16)

ASCE 7-22ASCE 7-16Flag of United States

Get balanced and unbalanced snow loads for sloped and flat roofs to ASCE 7-16 Chapter 7. Inputs cover ground snow load, surface roughness, importance, exposure, pitch, and thermal condition. Drift loads are calculated for any lower roofs, adjacent structures and projections you enter.

14-day free trial • No credit card required

  • ASCE 7-16, Chapter 7

    Named standard on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 16 Jul 2026

    Version 14, latest calculation change

  • 1,400+ calculations

    In 2026 across 230+ organizations

What it calculates

Get balanced and unbalanced snow loads for sloped and flat roofs to ASCE 7-16 Chapter 7. Inputs cover ground snow load, surface roughness, importance, exposure, pitch, and thermal condition. Drift loads are calculated for any lower roofs, adjacent structures and projections you enter.

Who uses this calculator

US structural engineers calculating roof snow loads to ASCE 7-16 for framing design. Covers ground-to-roof conversion, balanced and unbalanced loads, drift loads on lower roofs, and rain-on-snow surcharge flagging in a single calculation.

Apply ground-to-roof snow load factors in one step, reviewed by an external engineer for defensible use.

How it calculates

The Snow Loads (ASCE 7-16) calculator computes balanced and unbalanced roof snow loads, drift loads, and rain-on-snow surcharges per ASCE 7-16 Chapter 7.

Flat roof snow load

The base calculation converts ground snow load (p_g) to flat roof snow load (p_f) using three adjustment factors:

p_f = 0.7 × C_e × C_t × I_s × p_g

  • C_e - roof exposure factor (0.9 fully exposed, 1.0 partially exposed, 1.2 sheltered)
  • C_t - thermal factor (1.0 for heated buildings, up to 1.3 for cold structures)
  • I_s - importance factor (0.8 to 1.2 based on risk category)

A minimum roof snow load p_m = I_s × p_g is also enforced for low-sloped roofs.

Sloped roof (balanced) snow load

The balanced design snow load on sloped roofs applies the roof slope factor (C_s):

p_s = C_s × p_f

C_s is determined separately for warm roofs, cool roofs, and cold roofs based on roof pitch and thermal condition. The governing design load is max(p_s, p_m).

Rain-on-snow surcharge

A rain-on-snow surcharge of 5 psf is added to the balanced snow load per ASCE 7-16 Cl. 7.10. It applies where p_g is 20 psf or less and the slope is below W/50 degrees. The unbalanced loads and the balanced snow depth used for drifts exclude this surcharge.

Unbalanced snow loads

Unbalanced loading is checked for gable roofs with pitches between 0.5:12 and 7:12. The windward side carries 0.3 × p_s and the leeward side carries p_s plus a surcharge, with p_s taken without rain-on-snow. Where the eave-to-ridge distance W is 20 ft or less, the leeward side carries a uniform load and the windward side carries none. For wider roofs, the leeward surcharge is h_d × gamma / sqrt(S). Here gamma is snow density and S is roof slope run per unit rise. Unbalanced loads are not required outside the 0.5:12 to 7:12 pitch range.

Snow drift loads

Leeward and windward drifts are calculated on lower roofs and adjacent structures, and windward drifts at roof projections and parapets. The drift height h_d follows the ASCE 7-16 Figure 7.6-1 relationship, from the upwind fetch length, ground snow load and importance factor. Windward drifts use 0.75 × h_d.

On lower roofs, projections and parapets, drift surcharge pressure is h_d × gamma over a width of 4 × h_d from the step. Where the drift exceeds the clear height, the pressure is limited to gamma × clear height and the width is adjusted, capped at 8 times the clear height. Drifts on adjacent structures are reduced for the horizontal separation. Drifts are not required where the clear height is 20% or less of the balanced snow depth. A note flags the exemption for projection sides less than 15 ft long.

Outputs

The calculator reports p_f, p_s, p_design, rain-on-snow surcharge flag, unbalanced leeward and windward pressures, and drift heights and pressures for each lower roof or projection entered. All values reference the governing ASCE 7-16 clause.

Tested against worked examples

Each case shown is a worked example the calculator has been tested and verified against.

Example 2.7

Breyer

Textbook

Example 2.8

Breyer

Textbook

Example 4.1

Structural Load Determination

Textbook

Example 4.2

Structural Load Determination

Textbook

Example 4.6

Structural Load Determination

Textbook

What engineers say

Engineer
VQ Design

“I like that Calcs.com shows the code reference section for each calculation and function. That means every time I use it, there's a potential for me to learn something.”

Lawrence Bowen

Founding Principal, CPBD, VQ Design

Engineer

“Calcs.com simplified my beam analysis. It made structural checks easy and impressively fast.”

Aaron D. Obermiller, P.E.

Engineer, REO Engineering

Frequently asked questions

Access this calculator and 100+ more

All verified, standards-aligned. Start a free trial - no credit card required.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.