Wood Column (LRFD, NDS 2018)

NDS 2024NDS 2018Flag of United States

Column loads link from beam reactions above to footing calculations below - change a load once and all linked calculations update automatically. Design wood columns and studs to NDS 2018 LRFD with checks for axial compression, column stability factor Cp, combined axial and biaxial bending interaction per §3.9, and bearing.

14-day free trial • No credit card required

  • NDS 2018 (LRFD)

    Named standard on every check

  • Clause on every result

    Formula, inputs and reference visible

  • Updated 21 Aug 2026

    Version 148, latest calculation change

  • 670+ calculations

    In 2026 across 97 organizations

Start from your design scenario, not a generic setup

Each preset sets up this calculator for one design scenario, with the inputs that scenario usually takes already filled in. You change what differs on your project instead of re-entering every value on every job.

  • Generic Concentrically-Loaded Column
  • Interior Isolated Column
  • Exposed Outdoor Isolated Column
  • Interior Stud Wall
  • Exterior Stud Wall

What it calculates

Column loads link from beam reactions above to footing calculations below - change a load once and all linked calculations update automatically. Design wood columns and studs to NDS 2018 LRFD with checks for axial compression, column stability factor Cp, combined axial and biaxial bending interaction per §3.9, and bearing.

Who uses this calculator

Column loads link from beam reactions above to your footing calculations below automatically - no manual re-entry when loads change. All NDS 2018 LRFD column checks shown with code references: combined axial and bending interaction, column stability factor Cp, and buckling about both axes.

How it calculates

Design method

This calculator implements Load and Resistance Factor Design (LRFD) per the 2018 National Design Specification for Wood Construction (NDS 2018). The factored demand must not exceed the adjusted factored resistance at every limit state:

φ × K_F × F_ref × (adjustment factors) ≥ factored demand

For axial compression, φ_c = 0.90. For bending, φ_b = 0.85. For shear, φ_v = 0.75.

Column stability factor and buckling

The column stability factor C_P is the central calculation for compression capacity. It is derived from the ratio of the Euler critical buckling stress F_cE to the adjusted reference compression stress F*_c:

F_cE = 0.822 × E'_min / (L_e / d)²

where L_e is the effective unbraced length on the axis being checked and d is the cross-section dimension resisting buckling on that axis. E'_min is the adjusted LRFD modulus of elasticity for stability, incorporating φ_s = 0.85 and the applicable wet service and temperature factors.

The stability factor C_P is then computed from NDS 2018 Eq. 3.7-1:

C_P = [1 + (F_cE / F_c)] / (2c) - √{[(1 + (F_cE / F_c)) / (2c)]² - (F_cE / F*_c) / c}

where c = 0.8 for sawn lumber and 0.9 for glulam and structural composite lumber (SCL). A separate C_P is computed for each principal axis using the corresponding effective slenderness ratio. The governing axis - the one yielding the lower C_P - controls the factored compression resistance.

Compression checks

Two independent factored compression checks are performed, one for each principal axis:

φ_c P'_n,x = φ_c × K_F,c × F_c × λ × C_M × C_t × C_F × C_i × C_P,x × A

Utilization (X-axis): P_u / φ_c P'_n,x ≤ 1.0

Utilization (Y-axis): P_u / φ_c P'_n,y ≤ 1.0

Combined axial compression and biaxial bending

For columns subject to simultaneous axial compression and bending about one or both axes, the calculator evaluates the NDS 2018 LRFD combined interaction equation per §3.9. P_cE,x and P_cE,y are the Euler buckling loads on each axis. The interaction utilization must be ≤ 1.0 across both combined equations.

Bending and shear

Adjusted factored bending resistance for each axis uses the beam stability factor C_L per NDS 2018 Appendix E. For columns fully braced on both faces, C_L = 1.0. The adjusted factored shear resistance is computed with φ_v = 0.75 and the applicable wet service and temperature factors. Utilization Vu / φVn must be ≤ 1.0.

Bearing

Bearing is checked at the top and base of the column per compression perpendicular to grain. The bearing area factor C_b may exceed 1.0 for bearing lengths under 6 inches located at least 3 inches from the member end. The utilization R_u / φ_c P'_n,⊥ must be ≤ 1.0.

Built-up columns

For nailed or bolted built-up (multi-ply) columns, the effective column stability factor C_P is reduced relative to an equivalent solid section of the same cross-section area. The calculator applies the built-up column reduction to C_P to account for reduced composite action between plies, consistent with NDS 2018 provisions for multi-ply assemblies such as doubled or tripled studs.