Wood Roof Tie (LRFD, NDS 2018)
Rafter loads link from upstream calculations directly - change span or loading and both the tie tension and all rafter checks update automatically. Designs wood collar ties and rafter ties to NDS 2018 LRFD, checking factored tension (Pu / φTn ≤ 1.0) and all phi-factor limit states for the rafter.
14-day free trial - no credit card required
What it calculates
Rafter loads link from upstream calculations directly - change span or loading and both the tie tension and all rafter checks update automatically. Designs wood collar ties and rafter ties to NDS 2018 LRFD, checking factored tension (Pu / φTn ≤ 1.0) and all phi-factor limit states for the rafter.
Code standards
- NDS 2018 (LRFD)
How it calculates
Rafter geometry and horizontal thrust
The calculator resolves the pitched rafter geometry from the horizontal span and roof pitch. For a rafter spanning from the ridge to the wall plate, the horizontal outward thrust at the wall plate that the tie must resist is derived from the tributary load and pitch angle:
H = (w × L / 2) / tan(θ)
where w is the total factored load per unit length of the rafter (dead plus live or snow under the governing ASCE 7 LRFD combination), L is the horizontal rafter span, and θ is the pitch angle. For a collar tie positioned at height y above the wall plate, the tie tension is amplified by the ratio of the full rafter height h to the tie height y:
Pu = H × (h / y)
Tie tension check
The factored tensile resistance of the tie member per NDS 2018 LRFD:
φTn = φ_t × K_F,t × F_t × λ × C_M × C_t × C_F × A_n
where φ_t = 0.80 for tension parallel to grain, K_F,t is the format conversion factor, λ is the time-effect factor for the governing load combination (0.8 for occupancy live, 1.15 for roof live or snow, 1.0 for wind), and A_n is the net cross-sectional area at connections. The utilization ratio Pu / φTn must be ≤ 1.0.
Rafter bending and shear checks
The rafter is modeled as a simply supported inclined member loaded by self-weight and the applied gravity load. The governing factored bending moment Mu occurs at or near mid-span, and the critical shear Vu is taken at the face of the support.
φMn = φ_b × K_F,b × F_b × λ × C_M × C_t × C_F × C_r × C_L × S
φVn = φ_v × K_F,v × F_v × λ × C_M × C_t × (2/3 × A)
where φ_b = 0.85 for bending and φ_v = 0.75 for shear. The beam stability factor C_L is computed from the slenderness ratio R_B based on the lateral bracing condition of the rafter. Both Mu / φMn and Vu / φVn must be ≤ 1.0.
Deflection check
Rafter mid-span deflection under serviceability load combinations is computed using beam bending theory for the inclined span. The calculator checks against a user-specified span-to-deflection ratio (default L/240 for total load). Long-term deflection includes the NDS creep multiplier for the sustained dead load component.
Time-effect factor and LRFD adjustment factors
All resistance values are adjusted by the time-effect factor λ, which parallels the ASD load duration factor C_D. For the governing load combination, λ takes values of 0.6 for permanent dead load only, 0.8 for occupancy live, 1.15 for roof live or snow, and 1.0 for wind. The calculator automatically selects the governing combination and applies the corresponding λ to each capacity term, along with the format conversion factor K_F and the applicable wet service, temperature, and size factors.
What engineers say

The biggest thing I noticed about Calcs.com that made me a believer was the load linking. That was a game-changer.
Matt Ward
Principal Engineer, Ward Engineering
Frequently asked questions
What does this calculator design?
What are the key inputs?
What does it check and output?
How does this differ from the ASD version?
When do I need a structural ridge beam instead of a tie?
Does this calculator support load linking with connected calculations?
Access this calculator and 100+ more
All verified, standards-aligned. Start a free trial - no credit card required.