What's New at Calcs.com? (March 2026)

Product UpdatesMarch 31, 2026

MWFRS Directional Procedure and parapet pressures in the ASCE 7-16 and 7-22 wind calculators.

Ati Aziz

Senior Growth Marketing Manager, Calcs.com

March adds two features to the ASCE 7-16 and ASCE 7-22 wind calculators: the MWFRS Directional Procedure and parapet wind pressures.

Get direction-dependent MWFRS pressures without working through Fig. 27.3-1 by hand

The MWFRS Directional Procedure in ASCE 7 Chapter 27 asks you to work out building ratios, look up pressure coefficients and repeat the process for each wind direction. Done by hand, every lookup is a chance to pick the wrong Cp value.

The ASCE 7-22 and ASCE 7-16 wind calculators now support the Directional Procedure for MWFRS. Enter the building geometry and wind direction, and Calcs.com produces design pressures for walls and roofs.

Region and standards: US, ASCE 7-22 and ASCE 7-16. Plan: Included in the Pro plan and every plan above it.

What's new:

  • Direction-dependent wind pressures on walls and roofs, calculated from building geometry and wind direction
  • L/B and h/L ratios calculated for you
  • Cp values taken from ASCE 7 Fig. 27.3-1, so you no longer reference the tables manually
  • Design pressures for MWFRS surfaces, with each step shown in the calculation

Check several wind directions and roof conditions in one calculation, with every value visible for review.

Wind Loads (ASCE 7-22): MWFRS Directional Procedure selected, with direction-dependent wall and roof pressures in the summary

Watch the MWFRS Directional Procedure walkthrough

Account for parapets in your wind pressures without manual adjustments

ASCE 7 requires parapet wind pressures at the top of the parapet, and the treatment differs between ASCE 7-16 and ASCE 7-22. Working that out by hand for each edition takes time.

The ASCE 7-16 and ASCE 7-22 wind calculators now include optional parapet modeling. Turn it on and enter the parapet height. The calculator then adjusts wind pressures to the top of the parapet in line with ASCE 7.

Region and standards: US, ASCE 7-22 and ASCE 7-16. Plan: Included in the Pro plan and every plan above it.

What's new:

  • An optional parapet toggle with a parapet height input
  • MWFRS parapet pressures using combined net coefficients
  • C&C parapet pressures for applicable cases, using zone-based logic
  • Edition differences handled for you, including directionality factor treatment and tornado load considerations in ASCE 7-22

Wind Loads (ASCE 7-22): windward and leeward parapet pressures from combined net pressure coefficients

Watch the parapet wind pressures walkthrough

Your feedback shapes what we build next, so let us know what you think of these updates.

Put your calculations in an environment that holds up under review

Calcs.com shows the standard edition, clause reference, and applied formula at every check, so a reviewer can evaluate the work without reconstructing it.

Start a 14-day free trial

Make decisions you can defend at review time

Share a calculation with the basis of design attached - inputs, formulas, and code references alongside the result.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.