November's releases are all for US projects. Three of them sit at or below grade: basement walls, grade beams and tall retaining wall stems. Cold-formed steel columns and masonry shear walls also pick up checks that used to mean a separate hand calculation.
Design basement walls to IBC 2024 or IBC 2021
A basement wall is propped at the top by the floor it carries, so it doesn't behave like a cantilever retaining wall. The stem can take negative moment as well as positive, which changes where the reinforcement goes. Working through sliding, lateral forces, and moment and shear in the stem and footing by hand is slow.
The Restrained (Basement) Retaining Wall calculator now comes in an IBC 2024 edition, and the IBC 2021 edition is out of beta. Pick the edition that matches your project and the load standard follows it.
Region and standards: US, IBC 2024 with ASCE 7-22 and ACI 318-19, or IBC 2021 with ASCE 7-16 and ACI 318-19. Plan: Both editions are included in the Pro plan and every plan above it.
What the calculator covers:
- Lateral earth pressure by Rankine theory, with retained soil at-rest or active
- Combined axial-flexural stem design, footing flexural checks and an optional shear key in the IBC 2024 edition
- Dead and live loads at the wall top, for more realistic restraint forces than deflection-only workflows
- The IBC 2021 edition excludes wind and seismic loads
Open the IBC 2024 edition or the IBC 2021 edition.

Watch the IBC 2021 edition walkthrough
Design grade beams as foundation seismic ties in one sheet
In higher seismic design categories, ACI 318-19 requires pile caps, and spread footings on soft sites, to be tied together. Grade beams are the usual way to do it. Designing one by hand means factoring each column's loads, deriving the tie force, and checking the beam in tension, compression, flexure and shear. It's easy to miss that the tie force acts in both directions and reduces the concrete shear strength.
Region and standards: US, ACI 318-19 and ASCE 7-22. Plan: Included in the Pro plan and every plan above it.
The new Grade Beam calculator puts the full seismic tie design in one sheet, with seismic load effects to ASCE 7-22:
- Column loads entered by load type, or linked straight from your column calculations
- Seismic tie force of 0.1·SDS times the greater column load (Cl. 18.13.4.3), checked in tension and compression
- Cl. 18.13.4.4 limits on minimum cross-section dimension and closed tie spacing
- Flexure at both faces and one-way shear from the soil overburden on a fixed-fixed span
- Axial-flexure and axial-shear interaction for the (1.2 + 0.2SDS)D + E and (0.9 − 0.2SDS)D + E combinations
- Cross-section, moment and shear diagrams with pass/fail checks
The structural engineer who built it estimates it replaces 2 to 3 hours of hand calculation per grade beam.

Watch the Grade Beam walkthrough
Step down retaining wall reinforcement partway up the stem
Tall cantilever retaining walls were checked as one uniform section, sized for the moment at the base. That's not how they're built. Structural engineers routinely step down bars, and often thickness, partway up the wall to save material and reduce congestion. At least four firms asked for this.
Region and standards: US, IBC 2024, ASCE 7-22, ACI 318-19, TMS 402-22 and CMU-TEC-001-23. Plan: Included in the Pro plan and every plan above it.
The Cantilever Retaining Wall (IBC 2024) calculator now has a Segmented Stem Reinforcement option, to ACI 318-19:
- Split the stem into two segments at a height you set, each with its own bar size and spacing
- Keep a constant stem thickness or vary it between segments
- The upper segment is designed for the moment and shear at its own base, not the full-height demand
- Flexure, shear and minimum reinforcement checked per segment, plus the lap splice at the transition
- Works for concrete and CMU stems

Watch the segmented stem walkthrough
Check laterally loaded cold-formed steel studs without a separate analysis
Cold-formed steel studs in exterior walls see wind or seismic pressure on top of axial load from above. The calculator used to support concentric axial design only. Checking a laterally loaded stud meant a separate beam analysis, then a hand calculation to combine the demands.
Region and standards: US, AISI S100-16 (2020) with S2-20. Plan: Included in the Basic plan and every plan above it.
The Cold-Formed Steel Column calculator now runs the full member check in one sheet, to AISI S100-16(2020) w/S2-20:
- Wind and seismic tributary widths and design pressures as inputs
- Shear, moment and deflection diagrams, with ASCE 7-16 strength and service load combinations
- Flexural strength as the least of yielding, global, local and distortional buckling (Cl. F1/F2), plus shear (Cl. G2.1)
- Combined bending and shear (Cl. H2) and combined axial load and bending (Cl. H1.2)
- A deflection check, L/240 by default
- Columns under axial load only keep the existing workflow, unchanged

Watch the Cold-Formed Steel Column lateral loads walkthrough
Design diaphragm anchor bolts in the masonry shear wall sheet
Anchoring floor and roof diaphragms to a masonry wall was a separate task. Structural engineers had to leave the wall sheet and build the projected cones by hand, then carry seven limit states with different strength reduction factors. The smallest nominal strength isn't always the governing design strength once those factors differ.
Region and standards: US, TMS 402/602-22. Plan: Included in the Pro plan and every plan above it.
The Masonry Shear Wall (LRFD) calculator now designs these anchor bolts to TMS 402/602-22, using the story loads you already entered:
- An optional toggle that leaves the existing wall design untouched when off
- Bent-bar or headed anchors, with bolt size, material, embedment, spacing and end distance as inputs
- Wall anchorage force to ASCE 7-22 Eq. 12.11-1, with the Sec. 14.4.5.1 factor of 2.0 on the seismic case outside SDC A
- Projected tension and shear areas per Sec. 6.3, truncated where wall faces, wall ends or neighboring bolts cut the cone
- Seven limit states, each with its own factor, and the governing failure mode reported beside the result
- Tension and shear interaction (Eq. 9-8) per shear direction, with a per-story design table

Watch the masonry anchor bolt walkthrough
Tell us what you think of these updates. Your feedback sets what we build next.