Concrete beams in Calcs.com now design for torsion to ACI 318-19. The ASCE 7 wind, snow and seismic calculators picked up provisions that used to send structural engineers back to hand calculations. Steel base plates now check uplift, welds and biaxial bending.
Design concrete beams for torsion without a side spreadsheet
Spandrel beams with a slab on one side, edge beams and beams carrying off-center loads all pick up torsion. Until now, the Concrete Beam calculator stopped at flexure and shear. Any beam with real torsional demand meant a separate hand calculation, often re-entering geometry and reinforcement you had already defined.
The calculator now designs for torsion to ACI 318-19 Chapter 22, alongside the flexure and shear checks it already ran.
Region and standards: US, ACI 318-19. Plan: Included in the Pro plan and every plan above it.
What's new:
- A threshold torsion check (ACI 318-19 §22.7.4.1) tells you whether torsion can be neglected
- Where it can't, full design: cracking and threshold torque, factored torsion Tu against φTn, and required longitudinal steel
- Closed stirrup demand combines shear and torsion, so the governing transverse steel comes from one calculation
- A maximum torsional stress check (§22.7.7.1) guards against crushing of the concrete strut
- Apply concentrated or distributed torsional loads at any location along each span

Watch the concrete beam torsion walkthrough
Wind loads to ASCE 7-16 and 7-22: fewer overrides, fewer hand calcs
Five updates landed in the Wind Loads calculator this month, most in both the ASCE 7-22 and ASCE 7-16 editions. Each one removes a case where you previously had to leave the sheet or override a value by hand.
Region and standards: US, ASCE 7-16 and ASCE 7-22. Plan: Included in the Pro plan and every plan above it.
- Gust effect factor calculated for your building (MWFRS)
- G is no longer fixed at 0.85. The calculator works through the rigid-building equations in Cl. 26.11.4 using the geometry and exposure you've already entered
- Each intermediate step (z̄, Iz̄, Lz̄, Q and G) is shown in the sheet so you can check the working
- The default is max(G calculated, 0.85), and manual override is still available
- MWFRS tornado pressures to ASCE 7-22 Chapter 32
- Tornado design for the main wind force resisting system, using the Directional Procedure, for essential facilities in tornado-prone regions
- Covers windward and leeward walls, sidewalls, all roof zones and parapets, alongside the components and cladding tornado checks already in the calculator
- Overhang area and parapet height for each wind zone
- Enter a different overhang area and parapet height per zone instead of one value for the whole building
- Pressures are recalculated zone by zone, so an irregular roofline no longer forces the worst case everywhere
- Open enclosure type for free roofs
- Carports, canopies, pavilions and agricultural sheds now get code pressures for both MWFRS and components and cladding
- Covers monoslope and gable free roofs, with the 16 psf minimums enforced
- Internal pressure and roof Cp reductions
- Internal pressure reduction factor Ri (Eq. 26.13-1) for partially enclosed buildings with one large unpartitioned volume, such as hangars and arenas
- Roof Cp reduction (Fig. 27.3-1, footnote b) for low-slope roofs where h/L ≥ 1.0, based on tributary area
- Both are opt-in, so existing sheets give the same results

Watch the walkthroughs:
- Gust effect factor
- MWFRS tornado pressures
- Per-zone overhang and parapet inputs
- Open enclosure type
- Internal pressure and roof Cp reductions
Check snow drift from a neighboring building
A lower roof next to a taller, separate building can collect drifting snow across the gap. The calculator previously had no way to check that case, so it meant a hand calculation and an outside reference. Lower-roof drift was also reported as a single value, even though leeward and windward drift can govern different members.
The Snow Loads calculator now handles both, in the ASCE 7-22 and ASCE 7-16 editions.
Region and standards: US, ASCE 7-16 and ASCE 7-22. Plan: Included in the Pro plan and every plan above it.
What's new:
- Adjacent structures drift (ASCE 7-22 §7.7.2): enter roof lengths and the vertical and horizontal separation to get leeward and windward drift for each gap
- Applicability checks from the standard set drift to zero where §7.7.2 doesn't apply
- Leeward and windward drift on lower roofs now appear in separate tables, each with drift width, height, pressure and total load

Watch the adjacent structures snow drift walkthrough
More seismic systems and flexible-diaphragm overstrength in one sheet
When the seismic force-resisting system you needed wasn't in the list, you had to look up R, Ω₀ and Cd by hand. The calculator also had no input for the overstrength reduction on flexible diaphragms.
The Seismic Analysis calculator closes those gaps for both ASCE 7-16 and 7-22.
Region and standards: US, ASCE 7-16 and ASCE 7-22. Plan: Included in the Pro plan and every plan above it.
What's new:
- More systems from Table 12.2-1, including steel moment frames, eccentrically braced and buckling-restrained braced frames, and ordinary concrete, precast and masonry shear walls, each with its R, Ω₀, Cd and height limits
- Flexible-diaphragm overstrength: Ω₀ is reduced by 0.5 where the standard allows (Table 12.2-1, footnote b)
- Redundancy factor ρ set from the Seismic Design Category, with a manual override, and reported for use downstream
- Optional accidental torsion amplification (Cl. 12.8.4.2) for non-flexible diaphragms
- New inputs default to off, so existing sheets return the same results

Watch the seismic systems and overstrength walkthrough
Design WF column base plates for uplift, welds and biaxial bending
Columns in braced frames, or governed by wind or seismic loads, often see net uplift, moment about both axes and welded connections. The Steel Base Plate calculator couldn't check those, and anchor layouts were fixed at 2×2.
Region and standards: US, ACI 318-19, AISC 360-22 and AISC Design Guide 1. Plan: Included in the Pro plan and every plan above it.
What's new:
- Net anchor tension and uplift, sized with the AISC Design Guide 1 cantilever method
- Column-to-base-plate fillet weld check (AISC 360-22 Cl. J2.4) for combined tension, shear and moment
- Biaxial bending interaction for both the plate and the anchor group
- Set the number of anchors per row and column, plus a deeper concrete pier, with breakout checks to ACI 318-19 Chapter 17
- Optional shear redistribution across anchor rows when anchors are welded to the plate (ACI 318-19 Cl. 17.7.2)
- Anchor tension, weld utilization and biaxial interaction each show as their own pass or fail check

Watch the steel base plate walkthrough
Tell us what you think of these updates, and what you'd like us to build next.
Put your calculations in an environment that holds up under review
Calcs.com shows the standard edition, clause reference, and applied formula at every check, so a reviewer can evaluate the work without reconstructing it.
Start a 14-day free trial