What's New at Calcs.com? (June 2026)

Product UpdatesJune 30, 2026

June updates: sliding snow in the ASCE 7-22 snow calculator, zone-by-zone stirrup spacing, masonry walls with openings, and AU timber floor vibration.

Ati Aziz

Senior Growth Marketing Manager, Calcs.com

June brought four calculator updates for structural engineers in the US and Australia. Each one moves a check that used to happen in a side spreadsheet or hand calculation into the calculator itself.

Sliding snow on lower roofs, calculated with the rest of your snow loads

Where a roof steps down, snow can slide off the upper roof and pile onto the lower one. The Snow Loads (ASCE 7-22) calculator already covered balanced, unbalanced, rain-on-snow and drift loads. Sliding snow had to be worked out by hand and added in separately.

Region and standards: US, ASCE 7-22. Plan: Included in the Pro plan and every plan above it.

It now runs in the same calculation. What's new:

  • Sliding snow surcharge on the lower roof to ASCE 7-22 Section 7.9
  • The full surcharge applies where the lower roof is at least 15 ft (4.6 m) wide, and reduces proportionally for narrower roofs
  • Where balanced snow already on the lower roof blocks the incoming sliding snow, the load is reduced accordingly
  • Applies to the lower roof only. Separated buildings and cases blocked by an obstruction are not covered

Snow Loads (ASCE 7-22): sliding snow pressure for the lower roof, with reduced sliding load and total superimposed snow load

Watch the Sliding Snow walkthrough

Detail stirrups zone by zone in the concrete beam calculator

Shear in a reinforced concrete beam is highest near the supports and drops toward mid-span. Structural engineers detail tighter stirrups at the ends and wider spacing in the middle. Until now, the concrete beam calculator (ACI 318-19) took one spacing for the whole beam. That meant either the tightest spacing everywhere or a separate check for each zone.

Region and standards: US, ACI 318-19. Plan: Included in the Pro plan and every plan above it.

You can now enter the spacing you intend to build. What's new:

  • Simply supported beams take three spacings: one for each end region and one for mid-span
  • Continuous beams take a spacing for each segment between supports, matching the detailing zones on your drawings
  • Each segment is checked on its own against ACI 318-19 minimum shear reinforcement and maximum stirrup spacing limits, including the tighter limit in high-shear zones
  • Each segment's factored shear demand Vu is checked against φVn = φ(Vc + Vs), calculated from the spacing and stirrup geometry you enter

Concrete Beam (ACI 318-19): stirrup spacing by beam zone, with support and mid-span segments each checked against maximum spacing

Watch the varying stirrup spacing walkthrough

Design masonry shear walls with openings, pier by pier

Most masonry shear walls have doors, windows or service penetrations. Designing them means splitting the wall into piers, sharing the load by stiffness, and checking every pier. By hand that's slow, so many designs ignore the openings and over-design, or rely on spreadsheets that are hard to check.

The Masonry Shear Wall (LRFD) calculator now runs the Segmented Pier Method for reinforced and unreinforced walls under in-plane lateral and gravity loads.

Region and standards: US, TMS 402/602-22. Plan: Included in the Pro plan and every plan above it.

What's new:

  • Define the wall geometry, opening positions and sizes, material properties, and dead, live, wind and seismic load cases
  • Piers are identified automatically, and shear and axial demand is distributed by pier stiffness
  • Pier height-to-length ratios and fixity conditions are derived from the opening layout
  • Every pier is checked for in-plane shear, axial capacity, and combined flexure and axial interaction
  • Results show demand-to-capacity ratios pier by pier, with the piers that control the wall design flagged

Masonry Shear Wall (LRFD): shear and flexure utilization for every pier and story, with the governing criterion

Watch the masonry walls with openings walkthrough

Timber floor vibration checked to AS 1720.1 in the same sheet as strength

A timber floor can carry its load and still bounce underfoot. In Australia, AS 1720.1:2010 sets out a vibration check for this. Until now it ran outside the Timber Complex Beam calculator, so the numbers could fall out of step after a design change.

The check now runs inside the calculator and updates whenever the span, section or loading changes.

Region and standards: Australia, AS 1720.1:2010. Plan: Included in the Basic plan and every plan above it.

What's new:

  • The 1 kN imposed point load check from AS 1720.1:2010 Appendix E, with a 2 mm deflection limit
  • Always on for Floor Joist presets, and available through the Vibration Checks input for Floor Bearer, Floor Lintel and Generic Beam presets
  • Single spans use the actual support conditions to pick the right formula: pin-pin, pin-fix, fix-pin or fix-fix
  • Multi-span beams find the governing span automatically, treating end spans as propped cantilevers and interior spans as fixed-fixed
  • I-joists include shear deformation in the deflection
  • Floors acting as a grid reduce the imposed load by a grid factor to account for load sharing
  • Vibration Deflection appears in the Summary with a utilization ratio against the 2 mm limit. Expand it to see the formula, its description and the AS 1720.1:2010 Appendix E reference

Timber Complex Beam (AS 1720.1:2010): Vibration Deflection in the Summary for a Floor Joist, with its utilization against the 2 mm limit and the Appendix E description

Watch the timber floor vibration walkthrough

Tell us how these updates work on your projects, and what you'd like us to build next.

Put your calculations in an environment that holds up under review

Calcs.com shows the standard edition, clause reference, and applied formula at every check, so a reviewer can evaluate the work without reconstructing it.

Start a 14-day free trial

Make decisions you can defend at review time

Share a calculation with the basis of design attached - inputs, formulas, and code references alongside the result.

Linking a calculation to a column in Calcs.com, with the AISC Steel Construction Manual reference attached

We use analytics cookies to understand how you use this site and improve our content. See our privacy policy and cookie policy for details.